ANTI-PINCH SYSTEM DOES NOT OPERATE NORMALLY (DRIVER SIDE)

PWC-79

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

ANTI-PINCH SYSTEM DOES NOT OPERATE NORMALLY (DRIVER SIDE)

Diagnosis Procedure

INFOID:0000000003826046

1.

PERFORM INITIALIZATION PROCEDURE

Initialization procedure is executed and operation is confirmed.
Refer to 

PWC-6, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Require-

ment"

.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

CHECK ENCODER CIRCUIT

Check encoder circuit.
Refer to 

PWC-29, "Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to 

GI-35, "Intermittent Incident"

.

NO

>> GO TO 1.

PWC-80

< SYMPTOM DIAGNOSIS >

POWER WINDOW RETAINED POWER OPERATION DOES NOT OPERATE 

PROPERLY

POWER WINDOW RETAINED POWER OPERATION DOES NOT OPER-
ATE PROPERLY

Diagnosis Procedure

INFOID:0000000003857788

1.

CHECK DOOR SWITCH

Check door switch. 
Refer to 

PWC-27, "Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the malfunctioning parts.

2.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to 

GI-35, "Intermittent Incident"

.

NO

>> GO TO 1.

AUTO OPERATION DOES NOT OPERATE BUT MANUAL OPERATE NORMAL-

LY (DRIVER SIDE)

PWC-81

< SYMPTOM DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

AUTO OPERATION DOES NOT OPERATE BUT MANUAL OPERATE NOR-
MALLY (DRIVER SIDE)

Diagnosis Procedure

INFOID:0000000003826047

1.

PERFORM INITIALIZATION PROCEDURE

Initialization procedure is executed and operation is confirmed.
Refer to 

PWC-6, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Require-

ment"

.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 2.

2.

CHECK ENCODER

Check encoder. 
Refer to 

PWC-29, "Component Function Check"

.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the malfunctioning parts.

3.

CONFIRM THE OPERATION

Confirm the operation again.

Is the result normal?

YES

>> Check intermittent incident. Refer to 

GI-35, "Intermittent Incident"

.

NO

>> GO TO 1.

PWC-82

< SYMPTOM DIAGNOSIS >

POWER WINDOW LOCK SWITCH DOES NOT FUNCTION

POWER WINDOW LOCK SWITCH DOES NOT FUNCTION

Diagnosis Procedure

INFOID:0000000003826048

1.

REPLACE POWER WINDOW MAIN SWITCH 

Replace power window main switch. 

>> Refer to 

PWC-85, "Removal and Installation"

.

 

 

 

 

 

 

 

Content   ..  926  927  928  929   ..