EXL-242 < COMPONENT DIAGNOSIS > [HALOGEN TYPE] HAZARD SWITCH Does continuity exist? YES >> Repair the harnesses or connectors. NO >> GO TO 4. 4. CHECK HAZARD SWITCH GROUND OPEN CIRCUIT Check continuity between the hazard switch harness connector and the ground. Does continuity exist? YES >> Replace the hazard switch. NO >> Repair the harnesses or connectors. Hazard switch Ground Continuity Connector Terminal M45 2 Not existed Hazard switch Ground Continuity Connector Terminal M45 1 Existed |