EC-130

< COMPONENT DIAGNOSIS >

[VQ25DE, VQ35DE]

TROUBLE DIAGNOSIS - SPECIFICATION VALUE

22.

CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”

1.

Start engine.

2.

Select “A/F ALPHA-B1”, “A/F ALPHA-B2” in “SPEC” of “DATA MONITOR” mode, and check that each
indication is within the SP value.

Is the measurement value within the SP value?

YES

>> Detect malfunctioning part of mass air flow sensor circuit and repair it. Refer to 

EC-150, "Diagno-

sis Procedure"

Then GO TO 29.

NO

>> GO TO 23.

23.

CHECK “MAS A/F SE-B1”

Select “MAS A/F SE-B1” in “SPEC” of “DATA MONITOR” mode, and check that the indication is within the SP
value.
Is the measurement value within the SP value?

YES

>> GO TO 24.

NO

>> More than the SP value: Replace mass air flow sensor, and then GO TO 29.

24.

REPLACE ECM

1.

Replace ECM.

2.

Refer to 

EC-14, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Require-

ment"

.

>> GO TO 29.

25.

CHECK INTAKE SYSTEM

Check for the cause of uneven air flow through mass air flow sensor. Refer to the following.
• Crushed air ducts
• Malfunctioning seal in air cleaner element
• Uneven dirt in air cleaner element
• Improper specification in intake air system
Is the inspection result normal?

YES

>> GO TO 27.

NO

>> Repair or replace malfunctioning part, and then GO TO 26.

26.

CHECK “B/FUEL SCHDL”

Select “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and check that the indication is within the SP
value.
Is the measurement value within the SP value?

YES

>> INSPECTION END

NO

>> Less than the SP value: GO TO 27.

27.

CHECK “MAS A/F SE-B1”

Select “MAS A/F SE-B1” in “SPEC” of “DATA MONITOR” mode, and check that the indication is within the SP
value.
Is the measurement value within the SP value?

YES

>> GO TO 28.

NO

>> Less than the SP value: Replace mass air flow sensor, and then GO TO 30.

28.

CHECK INTAKE SYSTEM

Check for the cause of air leak after the mass air flow sensor. Refer to the following.
• Disconnection, looseness, and cracks in air duct
• Looseness of oil filler cap
• Disconnection of oil level gauge
• Open stuck, breakage, hose disconnection, or cracks in PCV valve
• Disconnection or cracks in EVAP purge hose, stuck open EVAP canister purge volume control solenoid

valve

• Malfunctioning seal in rocker cover gasket
• Disconnection, looseness, or cracks in hoses, such as a vacuum hose, connecting to intake air system parts

TROUBLE DIAGNOSIS - SPECIFICATION VALUE

EC-131

< COMPONENT DIAGNOSIS >

[VQ25DE, VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

• Malfunctioning seal in intake air system, etc.

>> GO TO 30.

29.

CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”, AND “B/FUEL SCHDL”

Select “A/F ALPHA-B1”, “A/F ALPHA-B2”, and “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and
check that each indication is within the SP value. 

Is the measurement value within the SP value?

YES

>> INSPECTION END

NO

>> Detect malfunctioning part according to 

EC-400, "Symptom Table"

.

30.

CHECK “B/FUEL SCHDL”

Select “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and then check that the indication is within
the SP value.

Is the measurement value within the SP value?

YES

>> INSPECTION END

NO

>> Detect malfunctioning part according to 

EC-400, "Symptom Table"

.

EC-132

< COMPONENT DIAGNOSIS >

[VQ25DE, VQ35DE]

POWER SUPPLY AND GROUND CIRCUIT

POWER SUPPLY AND GROUND CIRCUIT

Diagnosis Procedure

INFOID:0000000003856508

1.

CHECK GROUND CONNECTION-I

1.

Turn ignition switch OFF.

2.

Check ground connection E38. Refer to Ground Inspection in 

GI-37, "Circuit Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace ground connection.

2.

CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I

1.

Disconnect ECM harness connector.

2.

Check the continuity between ECM harness connector and ground.

3.

Also check harness for short to power.

is the inspection result normal?

YES

>> GO TO 4.

NO

>> GO TO 3.

3.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors F121, E7
• Harness for open or short between ECM and ground

>> Repair open circuit, short to power in harness or connectors.

4.

CHECK ECM POWER SUPPLY CIRCUIT-I

1.

Reconnect ECM harness connector.

2.

Turn ignition switch OFF and then ON.

3.

Check the voltage between ECM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> GO TO 5.

5.

DETECT MALFUNCTIONING PART

Check the following.
• IPDM E/R connector E10
• 10A fuse (No. 44)
• Harness for open or short between ECM and fuse

ECM

Ground

Continuity

Connector

Terminal

F7

12

Ground

Existed

16

E16

107

108

111

112

ECM

Ground

Voltage

Connector

Terminal

E16

93

Ground

Battery voltage

POWER SUPPLY AND GROUND CIRCUIT

EC-133

< COMPONENT DIAGNOSIS >

[VQ25DE, VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

>> Repair open circuit, short to ground or short to power in harness or connectors.

6.

CHECK ECM POWER SUPPLY CIRCUIT-II

1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Check the voltage between ECM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> GO TO 9.

7.

CHECK ECM POWER SUPPLY CIRCUIT-III

1.

Turn ignition switch ON.

2.

Check the voltage between IPDM E/R harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Replace IPDM E/R.

8.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-35, "Intermittent Incident"

.

>> INSPECTION END

9.

CHECK ECM POWER SUPPLY CIRCUIT-IV

1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Check the voltage between ECM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 12.

NO

>> GO TO 10.

10.

CHECK ECM POWER SUPPLY CIRCUIT-V

1.

Disconnect ECM harness connector.

2.

Disconnect IPDM E/R harness connector.

3.

Check the continuity between ECM harness connector and IPDM E/R harness connector.

4.

Also check harness for short to ground and short to power.

Is the inspection result normal?

ECM

Ground

Voltage

Connector

Terminal

E16

105

Ground

After turning ignition switch OFF, battery 
voltage will exist for a few seconds, then 
drop to approximately 0 V.

IPDM E/R

Ground

Voltage

Connector

Terminal

F12

49

Ground

Battery voltage

53

ECM

Ground

Voltage

Connector

Terminal

F7

24

Ground

Battery voltage

ECM

IPDM E/R

Continuity

Connector

Terminal

Connector

Terminal

F7

24

F12

69