INSUFFICIENT COOLING HAC-111 < SYMPTOM DIAGNOSIS > [WITHOUT 7 INCH DISPLAY] C D E F G H J K L M A B HAC N O P NO-1 >> Air outlet does not change. Refer to . NO-2 >> Air inlet does not change. Refer to . NO-3 >> Discharge air temperature does not change. Refer to . NO-4 >> Blower motor does not operate normally. Refer to NO-5 >> Magnet clutch does not operate. Refer to 7. CHECK AMBIENT TEMPERATURE DISPLAY Check that there is not much difference between actual ambient temperature and indicated temperature on Is the inspection result normal? YES >> GO TO 8. NO >> Perform the diagnosis for the A/C auto amp. connection recognition signal. Refer to 8. CHECK DRIVE BELT Check tension of the drive belt. Refer to Is the inspection result normal? YES >> GO TO 9. NO >> Adjust or replace drive belt. 9. CHECK AIR LEAKAGE FROM DUCT Check duct and nozzle, etc, of the A/C system for air leakage. YES >> INSPECTION END NO >> Repair or replace parts according to the inspection results. |