TROUBLE DIAGNOSIS ATC-105 C D E F G H I K L M A B ATC Revision: 2006 August 2006 Murano 3. CHECK INTAKE SENSOR Refer to OK or NG OK >> 1. Replace unified meter and A/C amp. 2. Go to self-diagnosis ATC-48, "FUNCTION CONFIRMATION PROCEDURE" and perform self- diagnosis STEP-2. Confirm that code No. 20 is displayed. NG >> 1. Replace intake sensor. 2. Go to self-diagnosis ATC-48, "FUNCTION CONFIRMATION PROCEDURE" and perform self- diagnosis STEP-2. Confirm that code No. 20 is displayed. 4. CHECK CIRCUIT CONTINUITY BETWEEN INTAKE SENSOR AND UNIFIED METER AND A/C AMP. 1. Turn ignition switch OFF. 2. Disconnect unified meter and A/C amp. connector. 3. Check continuity between intake sensor harness connector 4. Check continuity between intake sensor harness connector OK or NG OK >> 1. Replace unified meter and A/C amp. 2. Go to self-diagnosis ATC-48, "FUNCTION CONFIRMATION PROCEDURE" and perform self- diagnosis STEP-2. Confirm that code No. 20 is displayed. NG >> Repair harness or connector. COMPONENT INSPECTION After disconnecting intake sensor connector M256, measure resis- If NG, replace intake sensor. 1 – 41 : Continuity should exist. 1 – Ground : Continuity should not exist. RJIA1811E Temperature ° C ( ° F) Resistance k Ω − 15 (5) 18.63 − 10 (14) 14.14 − 5 (23) 10.85 0 (32) 8.40 5 (41) 6.57 10 (50) 5.18 15 (59) 4.12 20 (68) 3.30 25 (77) 2.66 30 (86) 2.16 35 (95) 1.77 40 (104) 1.46 45 (113) 1.21 RJIA1812E |