содержание .. 365 366 367 368 ..
B2419 OPEN SWITCH DLK-79 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B DLK N O P YES >> GO TO 4. NO >> GO TO 3. 3. CHECK OPEN SWITCH CIRCUIT 1. Disconnect automatic back door control unit and back door lock assembly connector. 2. Check continuity between automatic back door control unit harness connector and back door lock assem- 3. Check continuity between automatic back door control unit harness connector and ground. Is the inspection result normal? YES >> Replace automatic back door control unit. Refer to DLK-368, "Removal and Installation" . NO >> Repair or replace harness. 4. CHECK OPEN SWITCH GROUND CIRCUIT Check continuity between back door lock assembly harness connector and ground. Is the inspection result normal? YES >> GO TO 5. NO >> Repair or replace back door lock assembly ground circuit. 5. CHECK OPEN SWITCH DLK-79, "Component Inspection" Is the inspection result normal? YES >> GO TO 6. NO >> Replace back door lock assembly. Refer to DLK-351, "DOOR LOCK : Removal and Installation" 6. CHECK INTERMITTENT INCIDENT GI-44, "Intermittent Incident" . >> INSPECTION END Component Inspection INFOID:0000000009718951 COMPONENT INSPECTION 1. CHECK OPEN SWITCH Check back door lock assembly (open switch). Is the inspection result normal? YES >> INSPECTION END Automatic back door control unit Back door lock assembly Continuity Connector Terminal Connector Terminal B8 20 D179 4 Existed Automatic back door control unit Ground Continuity Connector Terminal B8 20 Not existed Back door lock assembly Ground Continuity Connector Terminal D179 8 Existed Terminal Condition Continuity Back door lock assembly (open switch) 4 8 Back door lock Open Existed Fully closed/Half latch Not existed |