содержание .. 1074 1075 1076 1077 ..
PCS-66 < DTC/CIRCUIT DIAGNOSIS > [POWER DISTRIBUTION SYSTEM] POWER SUPPLY AND GROUND CIRCUIT POWER SUPPLY AND GROUND CIRCUIT BCM BCM : Diagnosis Procedure INFOID:0000000009722671 1. CHECK FUSE AND FUSIBLE LINK Check that the following fuse and fusible link are not blown. Is the fuse fusing? YES >> Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown. NO >> GO TO 2. 2. CHECK POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect BCM connectors. 3. Check voltage between BCM harness connector and ground. Is the measurement value normal? YES >> GO TO 3. NO >> Repair harness or connector. 3. CHECK GROUND CIRCUIT Check continuity between BCM harness connector and ground. Does continuity exist? YES >> INSPECTION END NO >> Repair harness or connector. Signal name Fuse and fusible link No. Battery power supply L 10 Terminals Voltage (Approx.) (+) ( − ) BCM Ground Connector Terminal M118 1 Battery voltage M119 11 BCM Ground Continuity Connector Terminal M119 13 Existed |