содержание .. 467 468 469 470 ..
SUPER LOCK ACTUATOR DLK-217 < DTC/CIRCUIT DIAGNOSIS > [TYPE 1] C D E F G H I J L M A B DLK N O P Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK BCM OUTPUT SIGNAL 1. Connect BCM connector. 2. Check voltage between BCM harness connector and ground. Is the inspection result normal? YES >> Check for internal short of each door lock actuator. NO >> Replace BCM. Refer to BCS-121, "Removal and Installation" . REAR RH REAR RH : Component Function Check INFOID:0000000010735196 1. CHECK FUNCTION 1. Select “DOOR LOCK” of “BCM” using CONSULT. 2. Select “SUPER LOCK” in “ACTIVE TEST” mode. 3. Touch “LOCK” or “UNLOCK” to check that it works normally. Is the inspection result normal? YES >> Super lock actuator is OK. NO >> Refer to DLK-217, "REAR RH : Diagnosis Procedure" REAR RH : Diagnosis Procedure INFOID:0000000010735197 1. CHECK DOOR LOCK ACTUATOR OUTPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect rear door lock assembly RH. 3. Check voltage between rear door lock assembly RH harness connector and ground. Is the inspection result normal? YES >> Replace rear door lock assembly RH. NO >> GO TO 2. 2. CHECK SUPER LOCK ACTUATOR CIRCUIT 1. Disconnect BCM, each door lock actuator and fuel filler lid lock actuator connector. 2. Check continuity between BCM harness connector and rear door lock assembly RH harness connector. BCM Ground Continuity Connector Terminal B46 124 Not existed 131 (+) (–) Condition Voltage BCM Connector Terminal B46 124 Ground Super lock Release 9 – 16 V 131 Set (+) (–) Condition Voltage Rear door lock assembly RH Connector Terminal D99 5 Ground Super lock Release 9 – 16 V 6 Set |