содержание .. 446 447 448 449 ..
B2420 CLOSE SWITCH DLK-133 < DTC/CIRCUIT DIAGNOSIS > [TYPE 1] C D E F G H I J L M A B DLK N O P 1. Turn ignition switch OFF. 2. Disconnect back door lock assembly connector. 3. Check voltage between back door lock assembly harness connector and ground. Is the inspection result normal? YES >> GO TO 6. NO >> GO TO 5. 5. CHECK CLOSE SWITCH CIRCUIT 1. Disconnect automatic back door control unit connector. 2. Check continuity between automatic back door control unit harness connector and back door lock assem- 3. Check continuity between automatic back door control unit harness connector and ground. Is the inspection result normal? YES >> Replace automatic back door control unit. Refer to DLK-327, "Removal and Installation" . NO >> Repair or replace harness. 6. CHECK CLOSE SWITCH GROUND CIRCUIT Check continuity between back door lock assembly harness connector and ground. Is the inspection result normal? YES >> GO TO 7. NO >> Repair or replace harness. 7. CHECK INTERMITTENT INCIDENT GI-44, "Intermittent Incident" . Is the inspection result normal? YES >> GO TO 8. NO >> Repair or replace harness. 8. REPLACE BACK DOOR LOCK ASSEMBLY 1. Replace back door lock assembly. Refer to DLK-312, "DOOR LOCK : Removal and Installation" . 2. Erase DTC. 3. Perform DTC CONFIRMATION PROCEDURE for DTC 2420. . Is the inspection result normal? YES >> INSPECTION END NO >> Replace automatic back door control unit. Refer to DLK-327, "Removal and Installation" . (+) (–) Voltage (Approx.) Back door lock assembly Connector Terminal D172 5 Ground 12.2 V Automatic back door control unit Back door lock assembly Continuity Connector Terminal Connector Terminal B24 5 D172 5 Existed Automatic back door control unit Ground Continuity Connector Terminal B24 5 Not existed Back door lock assembly Ground Continuity Connector Terminal D172 8 Existed |