содержание .. 1858 1859 1860 1861 ..
INTRUDER SENSOR CANNOT BE DEACTIVATED SEC-207 < SYMPTOM DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P INTRUDER SENSOR CANNOT BE DEACTIVATED Diagnosis Procedure INFOID:0000000010926580 1. CHECK SENSOR CANCEL SWITCH Check sensor cancel switch. SEC-196, "Diagnosis Procedure" . Is the inspection result normal? YES >> GO TO 2. NO >> Replace sensor cancel switch. 2. REPLACE SIREN CONTROL UNIT 1. Replace siren control unit. 2. Confirm the operation after replacement. Is the inspection result normal? YES >> INSPECTION END NO >> GO TO 3. 3. REPLACE BCM BCS-121, "Removal and Installation" Is the inspection result normal? YES >> INSPECTION END NO >> Check intermittent incident. Refer to GI-44, "Intermittent Incident" . |