содержание .. 1854 1855 1856 1857 ..
SECURITY INDICATOR LAMP SEC-191 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P NO >> GO TO 5. 4. REPLACE BCM BCS-121, "Removal and Installation" . >> INSPECTION END 5. CHECK SECURITY INDICATOR LAMP CIRCUIT 1. Disconnect combination meter connector. 2. Check continuity between combination meter harness connector and BCM harness connector. 3. Check continuity between combination meter harness connector and ground. Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-151, "Removal and Installation" NO >> Repair or replace harness. Combination meter BCM Continuity Connector Terminal Connector Terminal M34 7 M87 75 Existed Combination meter Ground Continuity Connector Terminal M34 7 Not existed |