содержание .. 1019 1020 1021 1022 ..
STOP/START OFF SWITCH EC-1213 < DTC/CIRCUIT DIAGNOSIS > [R9M] C D E F G H I J K L M A EC N P O Is the inspection result normal? YES >> GO TO 5. NO >> GO TO 4. 4. CHECK STOP/START OFF SWITCH INPUT SIGNAL CIRCUIT 1. Disconnect BCM harness connector. 2. Check the continuity between BCM harness connector and stop/start OFF switch harness connector. 3. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> Check BCM power supply and ground circuit. NO >> Repair or replace error-detected parts. 5. CHECK STOP/START OFF SWITCH GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Check the continuity between stop/start OFF switch harness connector and ground. 3. Also check harness for short to ground and to power. Is the inspection result normal? YES >> GO TO 6. NO >> Repair or replace error-detected parts. 6. CHECK STOP/START OFF SWITCH Check the stop/start OFF switch. Refer to EC-1213, "Component Inspection" . Is the inspection result normal? YES >> INSPECTION END NO >> Replace stop/start OFF switch. Component Inspection INFOID:0000000010935924 1. CHECK STOP/START OFF SWITCH 1. Turn ignition switch OFF. 2. Disconnect stop/start OFF switch harness connector. 3. Check the continuity between stop/start OFF switch harness connectors as per the following condition. + − Voltage (Approx.) Stop/start OFF switch Connector Terminal M49 1 Ground Battery voltage + − Continuity BCM Stop/start OFF switch Connector Terminal Connector Terminal B47 99 M49 1 Existed − − Continuity Stop/start OFF switch Connector Terminal M49 2 Ground Existed |