COOLING FAN ECM-397 < DTC/CIRCUIT DIAGNOSIS > [MR20DD] C D E F G H I J K L M A ECM N P O 4. CHECK COOLING FAN MOTOR CIRCUIT-1 1. Check the continuity between cooling fan relay-2 harness connector and cooling fan motor harness con- 2. Also check harness for short to ground and to power. Is the inspection result normal? YES >> GO TO 5. NO >> Repair or replace error-detected parts. 5. CHECK COOLING FAN MOTOR CIRCUIT-2 1. Check the continuity between IPDM E/R harness connector and cooling fan motor-2 harness connector. 2. Also check harness for short to ground and to power. Is the inspection result normal? YES >> GO TO 9. NO >> GO TO 6. 6. CHECK COOLING FAN MOTOR CIRCUIT-3 1. Disconnect cooling fan resistor. 2. Check the continuity between cooling fan resistor harness connector and cooling fan motor harness con- Is the inspection result normal? YES >> GO TO 7. NO >> Repair or replace error-detected parts. 7. CHECK COOLING FAN MOTOR CIRCUIT-4 1. Check the continuity between IPDM E/R harness connector and cooling fan resistor harness connector. 2. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 8. NO >> Repair or replace error-detected parts. 8. CHECK COOLING FAN RESISTOR + − Continuity Cooling fan relay-2 Cooling fan motor Connector Terminal Connector Terminal F69 2 F39 1 Exisited + − Continuity IPDM E/R Cooling fan motor Connector Terminal Connector Terminal F88 69 F39 1 Existed + − Continuity Cooling fan resistor Cooling fan motor Connector Terminal Connector Terminal F68 2 F39 1 Existed + − Continuity IPDM E/R Cooling fan resistor Connector Terminal Connector Terminal F88 69 F68 1 Existed |