Nissan Qashqai J11. Manual - part 2184

 

  Index      Nissan     Nissan Qashqai J11 - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  2182  2183  2184  2185   ..

 

 

Nissan Qashqai J11. Manual - part 2184

 

 

DAS-150

< DTC/CIRCUIT DIAGNOSIS >

[DRIVER ASSISTANCE SYSTEM]

U1302 CAMERA POWER VOLT

LHD models

RHD models

Is the inspection result normal?

YES

>> Replace side camera RH. Refer to 

AV-269, "Removal and Installation"

.

NO

>> Repair or replace harness or connectors.

WITHOUT PUMP CONTROL UNIT

1.

CHECK AVM CAMERA DATA MONITOR ITEMS

Check “F-CAMERA IMAGE SIGNAL”, “REAR CAMERA IMAGE SIGNAL”, “DR-SIDE CAMERA IMAGE SIG”
and “PA-SIDE CAMERA IMAGE SIG” in “DATA MONITOR” of “AVM” using CONSULT.

Is “OK” displayed for all cameras?

YES

>> Refer to 

GI-41, "Intermittent Incident"

.

NO-1 (Front camera)>>GO TO 2.
NO-2 (Rear camera)>>GO TO 5.
NO-3 (Side camera LH)>>GO TO 8.
NO-4 (Side camera RH)>>GO TO 11.

2.

CHECK FRONT CAMERA POWER SUPPLY (CAMERA)

1.

Turn ignition switch ON.

2.

Check voltage between front camera connector and ground.

Is the inspection result normal?

YES

>> Replace front camera. Refer to 

AV-268, "Removal and Installation"

.

NO

>> GO TO 3.

3.

CHECK FRONT CAMERA POWER SUPPLY (AROUND VIEW MONITOR CONTROL UNIT)

Check voltage between around view monitor control unit connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Replace around view monitor control unit. Refer to 

AV-267, "Removal and Installation"

.

4.

CHECK FRONT CAMERA POWER SUPPLY CIRCUIT CONTINUITY

1.

Turn ignition switch OFF.

2.

Disconnect around view monitor control unit connector and front camera connector.

3.

Check continuity between around view monitor control unit connector and front camera connector.

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M8

62

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M8

56

Not existed

Front camera

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

E106

2

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

M95

38

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Front camera

Continuity

Connector

Terminal

Connector

Terminal

M95

38

E106

2

Existed

DAS

U1302 CAMERA POWER VOLT

DAS-151

< DTC/CIRCUIT DIAGNOSIS >

[DRIVER ASSISTANCE SYSTEM]

C

D

E

F

G

H

I

J

K

L

M

B

N

P

A

4.

Check continuity between around view monitor control unit connector and ground.

Is the inspection result normal?

YES

>> Replace front camera. Refer to 

AV-268, "Removal and Installation"

.

NO

>> Repair or replace harness or connectors.

5.

CHECK REAR CAMERA POWER SUPPLY (CAMERA)

1.

Turn ignition switch ON.

2.

Check voltage between rear camera connector and ground.

Is the inspection result normal?

YES

>> Replace rear camera. Refer to 

AV-270, "Removal and Installation"

.

NO

>> GO TO 6.

6.

CHECK REAR CAMERA POWER SUPPLY (AROUND VIEW MONITOR CONTROL UNIT)

Check voltage between around view monitor control unit connector and ground.

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> Replace around view monitor control unit. Refer to 

AV-267, "Removal and Installation"

.

7.

CHECK REAR CAMERA POWER SUPPLY CIRCUIT CONTINUITY

1.

Turn ignition switch OFF.

2.

Disconnect around view monitor control unit connector and rear camera connector.

3.

Check continuity between around view monitor control unit connector and rear camera connector.

4.

Check continuity between around view monitor control unit connector and ground.

Is the inspection result normal?

YES

>> Replace rear camera. Refer to 

AV-270, "Removal and Installation"

.

NO

>> Repair or replace harness or connectors.

8.

CHECK SIDE CAMERA LH POWER SUPPLY (CAMERA)

1.

Turn ignition switch ON.

2.

Check voltage between side camera LH connector and ground.

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M95

38

Not existed

Rear camera

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

D86

1

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

M95

26

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Rear camera

Continuity

Connector

Terminal

Connector

Terminal

M95

26

D86

1

Existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M95

26

Not existed

DAS-152

< DTC/CIRCUIT DIAGNOSIS >

[DRIVER ASSISTANCE SYSTEM]

U1302 CAMERA POWER VOLT

LHD models

RHD models

Is the inspection result normal?

YES

>> Replace side camera LH. Refer to 

AV-269, "Removal and Installation"

.

NO

>> GO TO 9.

9.

CHECK SIDE CAMERA LH POWER SUPPLY (AROUND VIEW MONITOR CONTROL UNIT)

Check voltage between around view monitor control unit connector and ground.

LHD models

RHD models

Is the inspection result normal?

YES

>> GO TO 10.

NO

>> Replace around view monitor control unit. Refer to 

AV-267, "Removal and Installation"

.

10.

CHECK SIDE CAMERA LH POWER SUPPLY CIRCUIT CONTINUITY

1.

Turn ignition switch OFF.

2.

Disconnect around view monitor control unit connector and side camera LH connector.

3.

Check continuity between around view monitor control unit connector and side camera LH connector.

LHD models

RHD models

4.

Check continuity between around view monitor control unit connector and ground.

LHD models

RHD models

Side camera LH

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

D3

7

CAMERA switch is ON.

6.0 V

Side camera LH

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

D16

7

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

M95

30

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

M95

34

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Side camera LH

Continuity

Connector

Terminal

Connector

Terminal

M95

30

D3

7

Existed

Around view monitor control unit

Side camera LH

Continuity

Connector

Terminal

Connector

Terminal

M95

34

D16

7

Existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M95

30

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M95

34

Not existed

DAS

U1302 CAMERA POWER VOLT

DAS-153

< DTC/CIRCUIT DIAGNOSIS >

[DRIVER ASSISTANCE SYSTEM]

C

D

E

F

G

H

I

J

K

L

M

B

N

P

A

Is the inspection result normal?

YES

>> Replace side camera LH. Refer to 

AV-269, "Removal and Installation"

.

NO

>> Repair or replace harness or connectors.

11.

CHECK SIDE CAMERA RH POWER SUPPLY (CAMERA)

1.

Turn ignition switch ON.

2.

Check voltage between side camera RH connector and ground.

LHD models

RHD models

Is the inspection result normal?

YES

>> Replace side camera RH. Refer to 

AV-269, "Removal and Installation"

.

NO

>> GO TO 12.

12.

CHECK SIDE CAMERA RH POWER SUPPLY (AROUND VIEW MONITOR CONTROL UNIT)

Check voltage between around view monitor control unit connector and ground.

LHD models

RHD models

Is the inspection result normal?

YES

>> GO TO 13.

NO

>> Replace around view monitor control unit. Refer to 

AV-267, "Removal and Installation"

.

13.

CHECK SIDE CAMERA RH POWER SUPPLY CIRCUIT CONTINUITY

1.

Turn ignition switch OFF.

2.

Disconnect around view monitor control unit connector and side camera RH connector.

3.

Check continuity between around view monitor control unit connector and side camera RH connector.

LHD models

LHD models

4.

Check continuity between around view monitor control unit connector and ground.

Side camera RH

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

D27

7

CAMERA switch is ON.

6.0 V

Side camera RH

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

D40

7

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

M95

34

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Ground

Condition

Voltage

(Approx.)

Connector

Terminal

M95

30

CAMERA switch is ON.

6.0 V

Around view monitor control unit

Side camera RH

Continuity

Connector

Terminal

Connector

Terminal

M95

34

D27

7

Existed

Around view monitor control unit

Side camera RH

Continuity

Connector

Terminal

Connector

Terminal

M95

30

D40

7

Existed

 

 

 

 

 

 

 

Content   ..  2182  2183  2184  2185   ..