PCS-60 < BASIC INSPECTION > [IPDM E/R] CUMULATIVE BATTERY DISCHARGE CURRENT CLEAR CUMULATIVE BATTERY DISCHARGE CURRENT CLEAR Description INFOID:0000000010499185 CUMULATIVE BATTERY DISCHARGE CURRENT CLEAR is an operation to clear the cumulative value of Work Procedure INFOID:0000000010499186 1. CLEAR CUMULATIVE BATTERY DISCHARGE CURRENT VALUE 1. Turn ignition switch ON. 2. Select “CML B/DCHRG CRNT CLEAR” in “Work Support” mode of “IPDM E/R” using CONSULT. 3. Touch “CLEAR” to clear the cumulative value of battery discharge current. >> WORK END |