Content .. 1214 1215 1216 1217 ..
ANTI-HIJACK FUNCTION DOES NOT OPERATE DLK-133 < SYMPTOM DIAGNOSIS > [TYPE 1] C D E F G H I J L M A B DLK N O P ANTI-HIJACK FUNCTION DOES NOT OPERATE Diagnosis Procedure INFOID:0000000010434660 1. CHECK “DOOR LOCK–UNLOCK SET” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT. 2. Select “DOOR LOCK-UNLOCK SET” in “WORK SUPPORT” mode. 3. Check “DOOR LOCK-UNLOCK SET” in “WORK SUPPORT” DLK-47, "DOOR LOCK : CONSULT Function (BCM - DOOR LOCK) (Type 1)" Is the inspection result normal? YES >> GO TO 2 NO >> Set “DOOR LOCK-UNLOCK SET” in “WORK SUPPORT”. 2. REPLACE BCM 1. Replace BCM. Refer to BCS-132, "Removal and Installation" . 2. Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END NO >> Check intermittent incident. Refer to GI-41, "Intermittent Incident" . |