Nissan Juke (2014 year). Service Repair Manual - part 53

 

  Index      Manuals     Nissan Juke (2014 year) - Service and Repair Manual

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

Content      ..     51      52      53      54     ..

 

 

Nissan Juke (2014 year). Service Repair Manual - part 53

 

 

DOOR LOCK ACTUATOR

DLK-73

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

PASSENGER SIDE

PASSENGER SIDE : Component Function Check

INFOID:0000000009753973

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to 

DLK-72, "DRIVER SIDE : Diagnosis Procedure"

.

PASSENGER SIDE : Diagnosis Procedure

INFOID:0000000009753974

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect front door lock assembly (passenger side) connector.

3.

Check voltage between front door lock assembly (passenger side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace front door lock assembly (passenger side).

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector. 

2.

Check continuity between BCM harness connector and front door lock assembly (passenger side) har-
ness connector. 

(+)

(–)

Condition

Voltage

(Approx.)

BCM

Connector

Terminal

M69

66

Ground

Door lock and unlock switch

Unlock

12 V

65

Lock

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLK

UNLOCK

(+)

(–)

Condition

Voltage

(Approx.)

Front door lock assembly

(passenger side)

Connector

Terminal

D17

6

Ground

Door lock and unlock switch

Unlock

12 V

5

Lock

Revision: 2013 October

2014 JUKE

DLK-74

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR LOCK ACTUATOR

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

REAR LH

REAR LH : Component Function Check

INFOID:0000000009753975

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to 

DLK-72, "DRIVER SIDE : Diagnosis Procedure"

.

REAR LH : Diagnosis Procedure

INFOID:0000000009753976

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect rear door lock assembly LH connector.

3.

Check voltage between rear door lock assembly LH harness connector and ground.

BCM

Front door lock assembly (passenger side)

Continuity 

Connector

Terminal

Connector

Terminal

M69

59

D17

6

Existed

65

5

BCM

Ground

Continuity 

Connector

Terminal

M69

59

Not existed

65

(+)

(–)

Condition

Voltage

(Approx.)

BCM

Connector

Terminal

M69

59

Ground

Door lock and unlock switch

Unlock

12 V

65

Lock

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLK

UNLOCK

Revision: 2013 October

2014 JUKE

DOOR LOCK ACTUATOR

DLK-75

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> Replace rear door lock assembly LH.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector.

2.

Check continuity between BCM harness connector and rear door lock assembly LH harness connector. 

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

REAR RH

REAR RH : Component Function Check

INFOID:0000000009753977

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR LOCK” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

(+)

(–)

Condition

Voltage

(Approx.)

Rear door lock assembly LH

Connector

Terminal

D65

2

Ground

Door lock and unlock switch

Unlock

12 V

1

Lock

BCM

Rear door lock assembly LH

Continuity 

Connector

Terminal

Connector

Terminal

B10

55

D65

2

Existed

M69

65

1

BCM

Ground

Continuity 

Connector

Terminal

B10

55

Not existed

M69

65

(+)

(–)

Condition

Voltage

(Approx.)

BCM

Connector

Terminal

B10

55

Ground

Door lock and unlock switch

Unlock

12 V

M69

65

Lock

Monitor item

Status

DOOR LOCK

ALL LOCK

Door lock actuators

LOCK

ALL UNLK

UNLOCK

Revision: 2013 October

2014 JUKE

DLK-76

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR LOCK ACTUATOR

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to 

DLK-72, "DRIVER SIDE : Diagnosis Procedure"

.

REAR RH : Diagnosis Procedure

INFOID:0000000009753978

1.

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect rear door lock assembly RH connector.

3.

Check voltage between rear door lock assembly RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace rear door lock assembly RH.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector and all door lock assembly connector.

2.

Check continuity between BCM harness connector and rear door lock assembly RH harness connector. 

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK BCM OUTPUT SIGNAL

1.

Connect BCM connector.

2.

Check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Check for internal short of each door lock actuator.

NO

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

(+)

(–)

Condition

Voltage

(Approx.)

Rear door lock assembly RH

Connector

Terminal

D45

6

Ground

Door lock and unlock switch

Unlock

12 V

5

Lock

BCM

Rear door lock assembly RH

Continuity 

Connector

Terminal

Connector

Terminal

B10

55

D45

6

Existed

M69

65

5

BCM

Ground

Continuity 

Connector

Terminal

B10

55

Not existed

M69

65

(+)

(–)

Condition

Voltage

(Approx.)

BCM

Connector

Terminal

B10

55

Ground

Door lock and unlock switch

Unlock

12 V

M69

65

Lock

Revision: 2013 October

2014 JUKE

DOOR LOCK AND UNLOCK SWITCH

DLK-77

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DOOR LOCK AND UNLOCK SWITCH

Component Function Check

INFOID:0000000009753979

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door lock and unlock switch is OK.

NO

>> Refer to 

DLK-77, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009753980

1.

CHECK DOOR LOCK AND UNLOCK SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect power window main switch connector.

3.

Check signal between power window main switch harness connector and ground using oscilloscope.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK AND UNLOCK SWITCH CIRCUIT

1.

Disconnect BCM connector and power window main switch connector.

2.

Check continuity between BCM harness connector and power window main switch harness connector.

3.

Check continuity between BCM harness connector and ground.

Monitor item

Condition

Status

CDL LOCK SW 

Door lock and unlock switch

Lock

ON

Unlock

OFF

CDL UNLOCK SW 

Lock

OFF

Unlock

ON

(+)

(–)

Signal

(Reference value)

Power window main switch

Connector

Terminal 

D35

3

Ground

1.0 - 1.5 V

15

JPMIA0012GB

BCM

Power window main switch

Continuity 

Connector

Terminal

Connector

Terminal

M68

12

D35

3

Existed

13

15

Revision: 2013 October

2014 JUKE

DLK-78

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR LOCK AND UNLOCK SWITCH

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK DOOR LOCK AND UNLOCK SWITCH GROUND 

Check continuity between power window main switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK DOOR LOCK AND UNLOCK SWITCH

Refer to 

DLK-78, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace power window main switch. Refer to 

PWC-55, "Removal and Installation"

.

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-46, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000009753981

1.

CHECK DOOR LOCK AND UNLOCK SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect power window main switch connector.

3.

Check continuity between power window main switch terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace power window main switch.

BCM

Ground

Continuity

Connector

Terminal

M68

12

Not existed

13

Power window main switch

Ground

Continuity 

Connector

Terminal

D35

1

Existed

Power window main switch

Condition

Continuity

Terminal

3

1

Door lock and unlock 
switch

LOCK

Existed

UNLOCK

Not existed

15

LOCK

Not existed

UNLOCK

Existed

Revision: 2013 October

2014 JUKE

DOOR REQUEST SWITCH

DLK-79

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DOOR REQUEST SWITCH

Component Function Check

INFOID:0000000009753982

1.

CHECK FUNCTION

1.

Select “INTELLIGENT KEY” of “BCM” using CONSULT.

2.

Select “REQ SW-DR”, “REQ SW-AS” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Front door request switch is OK.

NO

>> Refer to 

DLK-79, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009753983

1.

CHECK DOOR REQUEST SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning front door request switch connector.

3.

Check voltage between malfunctioning front door request switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK DOOR REQUEST SWITCH CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between malfunctioning front door request switch harness connector and BCM harness
connector.

3.

Check continuity between malfunctioning front door request switch harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

NO

>> Repair or replace harness.

Monitor item

Condition

Status

REQ SW -DR

Driver side door request switch

Pressed

ON

Released

OFF

REQ SW -AS

Passenger side door request switch

Pressed

ON

Released

OFF

(+)

(–)

Voltage

(Approx.)

Front door request switch

Connector

Terminal

Driver side

D34

2

Ground

12 V

Passenger side

D15

1

Front door request switch

BCM

Continuity 

Connector

Terminal

Connector

Terminal

Driver side

D34

2

M70

75

Existed

Passenger side

D15

1

100

Front door request switch

Ground

Continuity 

Connector

Terminal

Driver side

D34

2

Not existed

Passenger side

D15

1

Revision: 2013 October

2014 JUKE

DLK-80

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR REQUEST SWITCH

3.

CHECK DOOR REQUEST SWITCH GROUND CIRCUIT

Check continuity between malfunctioning front door request switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK DOOR REQUEST SWITCH

Refer to 

DLK-80, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace malfunctioning front door request switch.

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-46, "Intermittent Incident"

.

>> INSPECTION END 

Component Inspection

INFOID:0000000009753984

1.

CHECK DOOR REQUEST SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning front door request switch connector.

3.

Check continuity between malfunctioning front door request switch terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace malfunctioning front door request switch.

Front door request switch

Ground

Continuity 

Connector

Terminal

Driver side

D34

1

Existed

Passenger side

D15

2

Front door request switch

Condition

Continuity

Terminal

1

2

Door request switch

Pressed

Existed

Released

Not existed

Revision: 2013 October

2014 JUKE

DOOR SWITCH

DLK-81

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DOOR SWITCH

Component Function Check

INFOID:0000000009753985

1.

CHECK FUNCTION

1.

Select “DOOR LOCK” of “BCM” using CONSULT.

2.

Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL”, “DOOR SW-RR”, “DOOR SW-BK” in “DATA
MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Door switch is OK.

NO

>> Refer to 

DLK-81, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009753986

1.

CHECK DOOR SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning door switch connector.

3.

Check signal between malfunctioning door switch harness connector and ground using oscilloscope.

Is the inspection result normal?

YES-1 >> Back door: GO TO 3.
YES-2 >> Other door: GO TO 4.
NO

>> GO TO 2.

2.

CHECK DOOR SWITCH CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between door switch harness connector and BCM harness connector.

Monitor item

Condition

Status

DOOR SW-DR

Driver side door

Open

On

Closed

Off

DOOR SW-AS

Passenger side door

Open

On

Closed

Off

DOOR SW-RL

Rear door LH

Open

On

Closed

Off

DOOR SW-RR

Rear door RH

Open

On

Closed

Off

DOOR SW-BK

Back door

Open

On

Closed

Off

(+)

(–)

Signal

(Reference value)

Door switch

Connector

Terminal

Driver side

B48

2

Ground

7.0 - 8.0 V

Passenger side

B49

Rear LH

B71

Rear RH

B53

Back door

D106

3

PKIB4960J

Revision: 2013 October

2014 JUKE

DLK-82

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR SWITCH

3.

Check continuity between door switch harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK BACK DOOR LOCK ASSEMBLY CIRCUIT

Check continuity between back door lock assembly harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK DOOR SWITCH

Refer to 

DLK-82, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace malfunctioning door switch.

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-46, "Intermittent Incident"

.

>> INSPECTION END 

Component Inspection

INFOID:0000000009753987

1.

CHECK DOOR SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning door switch connector.

3.

Check continuity between door switch terminals.

Door switch

BCM

Continuity 

Connector

Terminal

Connector

Terminal

Driver side

B48

2

B10

47

Existed

Passenger side

B49

45

Rear LH

B71

48

Rear RH

B53

46

Back door

D106

3

43

Door switch

Ground

Continuity 

Connector

Terminal

Driver side

B48

Not existed

Passenger side

B49

Rear LH

B71

Rear RH

B53

Back door

D106

3

Back door switch

Ground

Continuity 

Connector

Terminal

D106

4

Existed

Revision: 2013 October

2014 JUKE

DOOR SWITCH

DLK-83

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace malfunction door switch.

Door switch

Condition

Continuity

Terminal

Driver side

2

Ground part of door 

switch

Door switch

Pressed

Existed

Released

Not existed

Passenger side

Pressed

Existed

Released

Not existed

Rear LH

Pressed

Existed

Released

Not existed

Rear RH

Pressed

Existed

Released

Not existed

Back door

3

4

Back door lock as-

sembly

Lock

Existed

Unlock

Not existed

Revision: 2013 October

2014 JUKE

DLK-84

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

HAZARD FUNCTION

HAZARD FUNCTION

Component Function Check

INFOID:0000000009753988

1.

CHECK FUNCTION

1.

Select “INTELLIGENT KEY” of “BCM” using CONSULT.

2.

Select “FLASHER” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Hazard warning lamp circuit is OK.

NO

>> Refer to 

DLK-84, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009753989

1.

CHECK HAZARD SWITCH CIRCUIT

Refer to 

EXL-79, "Component Function Check"

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the malfunctioning parts.

2.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-46, "Intermittent Incident"

.

>> INSPECTION END

Monitor item

Status

FLASHER

LH

Front turn signal lamp LH

Turns ON

RH

Front turn signal lamp RH

Turns ON

OFF

Front turn signal lamp

Turns OFF

Revision: 2013 October

2014 JUKE

INTELLIGENT KEY BATTERY

DLK-85

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

INTELLIGENT KEY BATTERY

Component Inspection

INFOID:0000000009753990

1.

CHECK INTELLIGENT KEY BATTERY

Check by connecting a resistance (approximately 300 

) so that the

current value becomes about 10 mA.

Is the measurement value within the specification?

YES

>> INSPECTION END

NO

>> Replace Intelligent Key battery.

Standard

: Approx. 2.5 - 3.0 V

OCC0607D

Revision: 2013 October

2014 JUKE

DLK-86

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

INTELLIGENT KEY WARNING BUZZER

INTELLIGENT KEY WARNING BUZZER

Component Function Check

INFOID:0000000009753991

1.

CHECK FUNCTION

1.

Select “INTELLIGENT KEY” of “BCM” using CONSULT.

2.

Select “OUTSIDE BUZZER” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Intelligent Key warning buzzer is OK.

NO

>> Refer to 

DLK-86, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009753992

1.

CHECK FUSE

1.

Turn ignition switch OFF.

2.

Check 10 A fuse, [No. 13, located in fuse block (J/B)].

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.

2.

CHECK INTELLIGENT KEY WARNING BUZZER POWER SUPPLY CIRCUIT

1.

Disconnect Intelligent Key warning buzzer connector.

2.

Check voltage between Intelligent Key warning buzzer harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK INTELLIGENT KEY WARNING BUZZER CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and Intelligent Key warning buzzer harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

Monitor item

Status

OUTSIDE BUZZER

ON

Outside warning buzzer

Buzzer sounds

OFF

Buzzer does not sound

(+)

(–)

Voltage

(Approx.)

Intelligent Key warning buzzer

Connector

Terminal

E25

1

Ground

Battery voltage

BCM

Intelligent Key warning buzzer

Continuity 

Connector

Terminal

Connector

Terminal

M70

93

E25

3

Existed

BCM

Ground

Continuity 

Connector

Terminal

M70

93

Not existed

Revision: 2013 October

2014 JUKE

INTELLIGENT KEY WARNING BUZZER

DLK-87

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

4.

CHECK INTELLIGENT KEY WARNING BUZZER

Refer to 

DLK-87, "Component Inspection"

.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-90, "Removal and Installation"

.

NO

>> Replace Intelligent Key warning buzzer.

Component Inspection

INFOID:0000000009753993

1.

CHECK INTELLIGENT KEY WARNING BUZZER

1.

Turn ignition switch OFF.

2.

Disconnect Intelligent Key warning buzzer connector.

3.

Connect battery power supply directly to Intelligent Key warning buzzer terminals and check the opera-
tion.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace Intelligent Key warning buzzer.

Intelligent Key warning buzzer

Operation

Terminal

(+)

(

)

1

3

Buzzer sounds

Revision: 2013 October

2014 JUKE

DLK-88

< DTC/CIRCUIT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

KEY WARNING LAMP

KEY WARNING LAMP

Component Function Check

INFOID:0000000009753994

1.

CHECK FUNCTION

1.

Select “INTELLIGENT KEY” of “BCM” using CONSULT.

2.

Select “INDICATOR” in “ACTIVE TEST” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Key warning lamp is OK.

NO

>> Refer to 

DLK-88, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009753995

1.

CHECK KEY WARNING LAMP 

Refer to 

MWI-20, "On Board Diagnosis Function"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the malfunctioning parts.

2.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-46, "Intermittent Incident"

.

>> INSPECTION END

Monitor item

Status

INDICATOR

KEY ON

Key warning lamp

Turns ON

KEY IND

Blinks

OFF

Turns OFF

Revision: 2013 October

2014 JUKE

 

 

 

 

 

 

 