INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT INL-39 < DTC/CIRCUIT DIAGNOSIS > C D E F G H I J K M A B INL N O P Is the inspection result normal? YES >> Check for internal short circuit of each interior room lamp. NO >> Repair or replace harnesses. 3. CHECK INTERIOR ROOM LAMP POWER SUPPLY SHORT CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect the BCM connector. 3. Check continuity between BCM harness connector and ground. Is the inspection result normal? YES >> Replace BCM. Refer to BCS-94, "Removal and Installation" NO >> Repair or replace harnesses. BCM Each interior room lamp Continuity Connector Terminal Connector Terminal M69 56 Map lamp R4 4 Existed Luggage room lamp B11 1 BCM Ground Continuity Connector Terminal M69 56 Not existed |