AUTO A/C DIAGNOSIS TSB Revision AUTOMATIC AIR CONDITIONING 55B-129 STEP 3. Replace the lock sensor. YES : No action is necessary and testing is complete. .) Check that the air conditioning works normally. DATA LIST REFERENCE TABLE M1554005100051 MUT-II SCAN ITEM INSPECTION ITEM INSPECTION REQUIREMENT NORMAL VALUE A/M DAMPER 31 Air mixing damper Ignition switch: ON Damper position Opening degree (%) MAX. HOT Approx. 100 MAX. COOL Approx. 0 OUTSIDE TEMP 13 Outside air Ignition switch: ON Outside air EVAP TEMP 21 Air thermo sensor Ignition switch: ON The temperature of AIR OUT POS 32 Mode selection Ignition switch: ON Damper position Opening degree (%) FACE Approx. 0 FOOT Approx. 50 FOOT/DEF. Approx. 75 DEF. Approx. 100 PHOTO SNSR 25 Photo sensor Ignition switch: ON Amount of incident INSIDE TEMP 11 Inside air Ignition switch: ON Inside air HEATER TEMP 15 heater water Ignition switch: ON ON when heater °C (86 °F) or higher. |