Mitsubishi Lancer Evolution 7. Manual - part 400

 

 

HEATER, AIR CONDITIONER AND VENTILATION

-

Troubleshooting

55-7

Inspection procedure 5

Cold air not coming out from the air outlet

Probable cause

If cold air does not come out from the air outlet, the amount of refrigerant may

be inappropriate or the compressor circuit system may be defective.

D

Refrigerant line fault

D

Amount of refrigerant fault

D

Compressor fault

D

Compressor relay fault

D

Dual pressure switch fault

D

Engine-ECUfault

D

A/C-ECU fault

OK

NG

Repair

NG

Check the harness between the A/C compressor relay and the

ignition switch (IG2), and repair if necessary.

OK

Check the trouble

symptoms.

Check the following connectors:

<L.H.D.> C-12X, C-130, C-102, C-209, C-210

<R.H.D.> C-12X, C-128, D-102, C-209, C-210

NG

Repair

Check the following connectors:

<L.H.D.> C-12X, A-13, A-47.

<R.H.D.> C-12X, A-136, A-47.

OK

OK

Check the trouble

symptoms.

NG

OK

NG

Replace

OK

OK

OK

NG

Check the harness between the battery and the A/C

compressor relay., and repair if necessary.

OK

Check the trouble

symptoms.

Check the following connectors:

<L.H.D.> B-12X, A-43

<R.H.D.>B-12X, C-136.

(1) NG

Repair

NG

(2) NG

OK

Check the dual pressure switch.

OK

NG

Repair

Check the harness between the A/Compressor relay and the

A/Compressor.

NG

Repair

Check the following connectors: B-12X, C-126.

OK

Check the trouble

symptoms.

NG

OK

NG

Repair

Check the harness between the A/Compressor relay and the

Engine-ECU.

To the next page

Check refrigerant for leakage.

NG

Replace

NG

Replace

NG

NG

Replace

Check the amount of refrigerant.

Check the compressor relay.

Check the compressor magnetic clutch.

Check the refrigerant temperature switch.

Measure at the compressor relay B-12X.
D

Disconnect the connector and measure at the harness

side.

D

Ignition switch: ON

(1) Voltage between terminal 1 and body earth.

OK : Battery voltage

(2) Continuity between terminal 2 and body earth.

OK : Battery voltage

Refer to Inspection procedure 6 magnet clutch not working

normally.

HEATER, AIR CONDITIONER AND VENTILATION

-

Troubleshooting

55-8

Repair

Repair

NG

Replace the A/C-ECU .

Replace the Engine-ECU .

NG

Repair

Check the following connectors:

<L.H.D.> A-36, C-111, C-130, C-122, C-32.

<R.H.D.> A-36, C-111, C-128, C-122, C-32.

OK

Check the trouble

symptoms.

NG

OK

NG

Check the harness between the dual pressure switch and the

Engine-ECU.

Check the following connectors: C-32, C-111, A-36.

OK

NG

OK

NG

Check the harness between the dual pressure switch and the

A/C-ECU.

From the previous page

Check the trouble

symptoms.

Repair

NG

Inspection procedure 6

Magnet clutch not working normally

Probable cause

If the magnet clutch does not work normally, the field core or the compressor

may be defective.

D

Compressor fault

D

Field core fault

Replace the field core.

Is not the Compressor locked ?

NG

Replace the compressor and field core.

No

HEATER, AIR CONDITIONER AND VENTILATION

-

Troubleshooting

55-9

Inspection procedure 7

Condenser fan not working at all

Probable cause

If the condenser fan does not work at all, the condenser fan circuit system may

be defective.

D

Condenser fan motor fault

D

Harness or connector fault

D

Engine-ECU fault

NG

Check the harness betweenthe condenser fan relay (LO) and

the ignition switch (IG2) , and repair if necessary.

OK

Check the trouble

symptoms.

NG

Repair

NG

Replace

OK

Check the condenser fan motor. (Refer to P.55-40.)

NG

Check the following connectors: A-06X, C-135, C-102,

C-209, C-210.

OK

Measure at the condenser fan relay (LO) A-06X.
D

Disconnect the connector and measure at the harness

side.

D

Ignition switch: ON

D

Voltage between terminal 2 and body earth.

OK : Battery voltage

NG

Check the harness betweenthe condenser fan motor and body

earth, and repair if necessary.

OK

Check the trouble

symptoms.

Repair

NG

Check the following connectors: A-46.

NG

OK

Measure at the condenser fan motor A-46.
D

Disconnect the connector and measure at the harness

side.

D

Continuity between terminal 2 and body earth

OK : Continuity

NG

OK

Check the trouble

symptoms.

Repair

NG

Check the following connectors:

<L.H.D.> C-122, A-43, A-06X.

<R.H.D.> C-122, C-136, A-06X

Replace the Engine-ECU.

OK

Repair

NG

Check the harness betweenthe condenser fan relay (LO) and

the Engine-ECU.

HEATER, AIR CONDITIONER AND VENTILATION

-

Troubleshooting

55-10

Inspection procedure 8

Condenser fan not working only for LO

Probable cause

If the condenser fan does not work only for LO, the condenser fan circuit

system or the condenser fan relay (LO) circuit system may be defective.

D

Condenser fan motor fault

D

Condenser fan relay (LO) fault

D

Harness or connector fault

D

Engine-ECU fault

NG

Check the harness betweenthe condenser fan relay (LO) and

the ignition switch (IG2), and repair if necessary.

OK

Check the trouble

symptoms.

NG

Repair

NG

Replace

OK

Check the condenser fan motor. (Refer to P.55-40.)

Check the following connectors: A-06X, C-135, C-102,

C-209, C-210.

OK

NG

OK

Check the trouble

symptoms.

Repair

Check the following connectors: A-06X.

NG

NG

OK

Check the trouble

symptoms.

Repair

NG

Check the following connectors:

<L.H.D.> A-06X, A-43, C-122.

<R.H.D.> A-06X, C-136, C-122.

Replace the Engine-ECU .

OK

Repair

NG

Check the harness betweenthe condenser fan relay (LO) and

the Engine-ECU.

(2) NG

Measure at the condenser fan relay (LO) A-06X.
D

Disconnect the connector and measure at the junction box

side.

D

Ignition switch: ON

(1) Voltage between terminal 2 and body earth.

OK : Battery voltage

(2) Voltage between terminal 4 and body earth.

OK : Battery voltage

(1) NG

NG

Replace

OK

Check the condenser fan relay (LO) (Refer to P.55-23.)

NG

OK

Check the trouble

symptoms.

Repair

Check the following connectors: A-06X, A-45.

OK

Check the harness betweenthe condenser fan relay (LO) and

the condenser fan motor, and repair if necessary.

Check the harness betweenthe condenser fan relay (LO) and

the battery, and repair if necessary.

 

 

 

 

 

 

 