Mitsubishi Eclipse / Eclipse Spyder (2000-2002). Service and repair manual - part 691

 

  Index      Mitsubishi     Mitsubishi Eclipse / Eclipse Spyder (2000-2002). Service and repair manual

 

Search            

 

 

 

 

 

 

 

 

Content   ..  689  690  691  692   ..

 

 

Mitsubishi Eclipse / Eclipse Spyder (2000-2002). Service and repair manual - part 691

 

 

55-1

GROUP 55

HEATING AND AIR

 

CONDITIONING

CONTENTS

GENERAL INFORMATION . . . . . . . .

55-3

MANUAL A/C DIAGNOSIS . . . . . . . .

55-4

INTRODUCTION TO MANUAL A/C 
DIAGNOSIS  . . . . . . . . . . . . . . . . . . . . . . . . 

55-4

MANUAL A/C DIAGNOSTIC 
TROUBLESHOOTING STRATEGY . . . . . . 

55-5

SYMPTOM CHART. . . . . . . . . . . . . . . . . . . 

55-5

SYMPTOM PROCEDURES . . . . . . . . . . . . 

55-5

CHECK AT ECU TERMINAL  . . . . . . . . . . . 

55-18

TROUBLESHOOTING HINT. . . . . . . . . . . . 

55-19

SPECIAL TOOLS. . . . . . . . . . . . . . . .

55-20

ON-VEHICLE SERVICE. . . . . . . . . . .

55-20

REFRIGERANT LEVEL TEST  . . . . . . . . . . 

55-20

MAGNETIC CLUTCH TEST . . . . . . . . . . . . 

55-20

RECEIVER DRIER TEST . . . . . . . . . . . . . . 

55-21

PRESSURE SWITCH CHECK . . . . . . . . . . 

55-21

COMPRESSOR DRIVE BELT 
ADJUSTMENT  . . . . . . . . . . . . . . . . . . . . . . 

55-21

CHARGING  . . . . . . . . . . . . . . . . . . . . . . . . 

55-21

PERFORMANCE TEST  . . . . . . . . . . . . . . . 

55-22

REFRIGERANT LEAK REPAIR 
PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . 

55-23

COMPRESSOR NOISE CHECK  . . . . . . . . 

55-24

POWER RELAY CHECK  . . . . . . . . . . . . . . 

55-24

IDLE-UP OPERATION CHECK  . . . . . . . . . 

55-26

HEATER CONTROL ASSEMBLY AND 
A/C SWITCH . . . . . . . . . . . . . . . . . . . .

55-26

REMOVAL AND INSTALLATION  . . . . . . . . 

55-26

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55-29

HEATER UNIT, HEATER CORE, BLOWER 
ASSEMBLY, EVAPORATOR UNIT . .

55-30

REMOVAL AND INSTALLATION  . . . . . . . . 

55-30

BLOWER ASSEMBLY AND 
RESISTOR  . . . . . . . . . . . . . . . . . . . . .

55-32

REMOVAL AND INSTALLATION  . . . . . . . . 

55-32

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55-32

COMPRESSOR ASSEMBLY AND TENSION 
PULLEY  . . . . . . . . . . . . . . . . . . . . . . .

55-34

REMOVAL AND INSTALLATION  . . . . . . . . 

55-34

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55-36

COMPRESSOR MAGNETIC CLUTCH 
OPERATION INSPECTION  . . . . . . . . . . . . 

55-36

REVOLUTION PICK-UP SENSOR CHECK  

55-37

MAGNETIC CLUTCH  . . . . . . . . . . . . . . . . . 

55-37

CONDENSER AND CONDENSER FAN 
MOTOR . . . . . . . . . . . . . . . . . . . . . . . .

55-40

REMOVAL AND INSTALLATION  . . . . . . . . 

55-40

INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . 

55-41

REFRIGERANT LINE . . . . . . . . . . . . .

55-42

REMOVAL AND INSTALLATION  . . . . . . . . 

55-42

VENTILATORS . . . . . . . . . . . . . . . . . .

55-44

REMOVAL AND INSTALLATION  . . . . . . . . 

55-44

GENERAL INFORMATION

TSB Revision

HEATING AND AIR CONDITIONING

55-3

.

G EN ER A L IN FO R M ATIO N

M1552000100050

The heater system uses a two-way-flow full-air-mix 
system that features high performance and low 
operating noise. It includes an independent face air 
blowing function. In addition, an air purifier has been 
included.

SAFETY PRECAUTIONS

WARNING

Wear safety goggles and gloves when 
servicing the refrigeration system to prevent 
severe damage to eyes and hands.

Because R-134a refrigerant is a hydro fluorocarbon 
(HFC) which contains hydrogen atoms in place of 
chlorine atoms, it will not cause damage to the ozone 
layer.
Ozone filters out harmful radiation from the sun. To 
assist in protecting the ozone layer, Mitsubishi 
Motors Corporation recommends an R-134a 
refrigerant recycling device.
Refrigerant R-134a is transparent and colorless in 
both the liquid and vapor state. Since it has a boiling 
point of 

29.8

°

C (

21.64

°

F) at atmospheric pressure, 

it will be a vapor at all normal temperatures and 
pressures. The vapor is heavier than air, non-
flammable, and non-explosive. The following 
precautions must be observed when handling R-
134a.

WARNING

Do not heat R-134a above 40

°

C (104.0

°

F) or it 

may catch fire and explode.

R-134a evaporates so rapidly at normal atmospheric 
pressures and temperatures that it tends to freeze 
anything it contacts. For this reason, extreme care 
must be taken to prevent any liquid refrigerant from 
contacting the skin and especially the eyes. Always 
wear safety goggles when servicing the refrigeration 
part of the A/C system. Keep a bottle of sterile 
mineral oil handy when working on the refrigeration 
system.

1. Should any liquid refrigerant get into the eyes, use 

a few drops of mineral oil to wash them out. R-
134a is rapidly absorbed by the oil.

2. Next splash the eyes with plenty of cold water.

3. Call your doctor immediately even though 

irritation has ceased after treatment.

CAUTION

Keep R-134a containers upright when charging 
the system.
In most instances, moderate heat is required to bring 
the pressure of the refrigerant in its container above 
the pressure of the system when charging or adding 
refrigerant.
A bucket or large pan of hot water not over 40

°

(104.0

°

F) is all the heat required for this purpose. Do 

not heat the refrigerant container with a blow torch or 
any other means that would raise temperature and 
pressure above this temperature. Do not weld or 
steam clean on or near the system components or 
refrigerant lines.

WARNING

The leak detector for R-134a should be used 
to check for refrigerant gas leaks.

CAUTION

Do not allow liquid refrigerant to touch bright 
metal or it will be stained.
When metering R-134a into the refrigeration system 
keep the supply tank or cans in an upright position. If 
the refrigerant container is on its side or upside 
down, liquid refrigerant will enter the system and 
damage the compressor.
Refrigerant will tarnish bright metal and chrome 
surfaces, and in combination with moisture can 
severely corrode all metal surfaces.

Items

Specifications

Heater unit

Type

Two-way-flow full-air-mix system

Heater control assembly

Dial type

Compressor

Model

Scroll type <MSC90C>

Dual pressure 
switch kPa (psi)

High-pressure switch

ON 

 OFF: 2,942 (426.7), OFF 

 ON: 2,354 (341.4)

Low-pressure switch

ON 

 OFF: 196 (28.4), OFF 

 ON: 221 (32.1)

Refrigerant and quantity g (oz)

R-134a (HFC-134a), Approximately 415 

 435 (14.6 

 15.3)

MANUAL A/C DIAGNOSIS

TSB Revision

HEATING AND AIR CONDITIONING

55-4

OPERATION

Condenser fan and radiator fan control

For the operation of each fan, refer to GROUP 
14, Diagnosis - Symptom Chart 

P.14-3

.

Compressor control

When operating the air conditioning switch

The air thermo sensor, which senses the 
temperature of the air flowing out of the 
evaporator, deactivates the compressor at 5 

°

(41.0 

°

F) or below.

The dual pressure switch turns OFF when the 
refrigerant pressure becomes excessively high or 
low, thus protecting the compressor circuit. (See 
Table below.)

When the air thermo sensor is activated, the dual 
pressure switch is ON, and the ignition switch, 
blower switch, and air conditioning switch are 
ON, the A/C compressor relay is energized.

When operating the air outlet changeover control 

knob

When the air outlet changeover control knob is 
moved to DEFROSTER or DEFROSTER/FOOT 
position, the defroster switch, which is connected 
in series to the air conditioning switch, is turned 
on. The other compressor control than the above 
is the same as that when operating the air 
conditioning switch.

When compressor locks <vehicles with 3.0 L 

engine>

Since the compressor and alternator are driven 
by the same belt, the electric generating function 
of the alternator also stops when the belt is 
broken. In order to assure the electric generating 
function of the alternator, there is an A/C-ECU to 
prevent breaking of the belt due to slipping when 
the compressor locks. The A/C-ECU makes a 
comparative calculation of the compressor 
revolutions and the engine revolutions which are 
detected by the revolution pick-up sensor. When 
70% or more slip ratio continues for 3 seconds or 
more, the A/C compressor relay goes from on to 
off; at the same time, the operation display in the 
air conditioner switch blinks to announce an 
abnormality.

A/C Compressor Relay ON Conditions

M A N U A L A /C  D IA G N O S IS

INTRODUCTION TO MANUAL A/C DIAGNOSIS

M1552012200087

With this system, after the outside air or inside air is 
taken in through the damper, it is fed to the 
evaporator by the blower fan and motor and cooled. 
The air cooled by the air mix damper is mixed 
appropriately with the warmed air to achieve a 

comfortable temperature. If the A/C does not operate 
or the cooled air is not discharged, the machine 
components or relay may be faulty.

Ignition switch (IG2)

ON

NOTE: . A/C compressor relay is de-
energized when any one switch, sensor or 
control unit shown on the left turns off.

NOTE: . The 

marked device measures the 

temperature of the outlet air, and according 
to the control characteristics of the magnetic 
clutch for the compressor, the automatic 
compressor controller outputs the "HI" signal 
(12V). When air of 5

°

C (41.0

°

F) or less 

blows out of the evaporator, the compressor 
magnetic clutch will be turned off.

Blower switch

ON

Air conditioning switch or defroster switch

ON

Air thermo sensor

*

Dual pressure 
switch

Low-pressure side 221 kPa 
(32.1 psi) or higher

ON

High-pressure side 2,942 kPa 
(426.7 psi) or below

ON

A/C compressor relay driving transistor (within 
automatic compressor controller and engine control 
module <M/T>, powertrain control module <A/T>)

ON

 

 

 

 

 

 

 

Content   ..  689  690  691  692   ..