AUTOMATIC TRANSAXLE DIAGNOSIS TSB Revision AUTOMATIC TRANSAXLE 23A-81 STEP 4. Check the sensor output voltage at A/T control side. (2) Turn the ignition switch to the "ON" position. (3) Measure the voltage between terminal 1 and ground. • The voltage should measure between 4.5 and 4.9 volts. (4) Turn the ignition switch to the "LOCK" (OFF) position. YES : Go to Step 5. ACX02479 CONNECTOR: B-40 AK B-40 ACX02104 B-40 HARNESS AM |