MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS TSB Revision MULTIPORT FUEL INJECTION (MFI) <3.0L> 13B-127 STEP 8. Check the continuity at intake air temperature side. (2) Check for the continuity between terminal 5 and ground. • Should be less than 2 ohms. Q: Is the continuity normal? YES : Replace the ECM or PCM. Then go to Step 11. AK300078 3 4 5 1 2 6 7 CONNECTOR: B-14 AB B-14 (B) HARNESS AKX01409AI 7 6 5 4 3 2 1 B-14 HARNESS |