COMBINATION METER CHASSIS ELECTRICAL 54A-59 YES : Retest the system. NO : Repair the wiring harness. Step 6. Voltage measurement at combination (1) Disconnect combination meter connector C-02, and measure at the wiring harness side. (2) Turn the ignition switch to "ON" position. (3) Measure the voltage between terminal 39 and earth. OK: Battery voltage Q: Is the check result normal? YES : Go to Step 8. NO : Go to Step 7. AC310613 AX Connector: C-02 <LHD> Harness side 40 20 28 8 34 14 37 17 38 39 1918 35 36 1615 31 11 33 13 32 12 30 10 29 9 23 3 27 7 26 6 24 4 25 5 21 1 22 2 AC310631AU Connector: C-02 <RHD> Harness side 40 20 28 8 34 14 37 17 38 39 1918 35 36 1615 31 11 33 13 32 12 30 10 29 9 23 3 27 7 26 6 24 4 25 5 21 1 22 2 AC310507 40 20 28 8 34 14 37 17 38 39 1918 35 36 1615 31 11 33 13 32 12 30 10 29 9 23 3 27 7 26 6 24 4 25 5 21 1 22 2 DH Connector C-02 |