9J1–9 RESTRAINT CONTROL SYSTEM Chart B “AIR BAG” warning lamp comes “ON” Steady Step Action Yes No 1 1. When measurements are requested in this chart use 5–8840–0285–0 DVM with correct terminal adapter from 2. Ignition switch “OFF.” given in the scan tool instruction MANUAL. 4. Ignition switch “ON.” Dose scan tool indicate “No Data Received”? Go to Step 2 Go to Step 3 2 1. Ignition switch “OFF”. Is it securely connected to the SDM? Ignition switch “OFF” Replace SDM Go to Step 5 Connect SDM securely to de–activate shorting clip in SDM harness connector Go to Step 5 3 Using scan tool, request SRS data list. Is “ignition” less than 9 volts? Go to Step 4 Ignition switch “OFF” Replace SDM Go to Step 5 4 1. Ignition switch “OFF.” yellow 2–pin connector located at base of steering column and 3. Disconnect the connector of “SRS Warning Lamp” of instrument cluster. 4. Measure resistance from SDM harness connector terminal “7” to ground “6”. Does 5–8840–0285–0 display “OL” (Infinite)? Go to Chart A Replace SRS harness Go to Step 5 5 Reconnect all SRS components, ensure all components are Was this step finished? Repeat the “SRS Diagnostic System Check” Go to Step 5 |