EXL-84 < DTC/CIRCUIT DIAGNOSIS > [XENON TYPE] POWER SUPPLY AND GROUND CIRCUIT POWER SUPPLY AND GROUND CIRCUIT AFS CONTROL UNIT AFS CONTROL UNIT : Diagnosis Procedure INFOID:0000000006213953 1. FUSE INSPECTION Check that the following fuses are not fusing. Is the inspection result normal? YES >> GO TO 2. NO >> Repair the applicable circuit. And then replace the fuse. 2. CHECK POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect AFS control unit harness connector. 3. Turn ignition switch ON. 4. Check voltage between AFS control unit harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair harness or connector. 3. CHECK GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Check continuity between AFS control unit harness connectors and ground. Is the inspection result normal? YES >> Power supply and ground circuit are normal. NO >> Repair harness or connector. Signal name Connection position Fuse No. Capacity Ignition power supply FUSE BLOCK (J/B) 3 10 A (+) ( − ) Voltage (Approx.) AFS control unit Connector Terminal M135 1 Ground Battery voltage AFS control unit Ground Continuity Connector Terminal M135 25 Existed |