KEY WARNING LAMP DLK-105 < COMPONENT DIAGNOSIS > [INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B DLK N O P KEY WARNING LAMP Description INFOID:0000000001723453 Performs operation method guide and warning together with buzzer. Component Function Check INFOID:0000000001723454 1. CHECK FUNCTION With CONSULT-III Check the operation with “INDICATOR” in “Active Test” mode with CONSULT-III. Is the inspection result normal? Yes >> Key warning lamp in combination meter is OK. No >> Refer to DLK-105, "Diagnosis Procedure" Diagnosis Procedure INFOID:0000000001723455 1. CHECK KEY WARNING LAMP MWI-50, "COMBINATION METER : Diagnosis Procedure" Is the inspection result normal? Yes >> GO TO 2. No >> Repair or replace key warning lamp circuit. 2. CHECK INTERMITTENT INCIDENT GI-38, "Intermittent Incident" . >> INSPECTION END Test item Condition INDICATOR :BLUE ON Key warning lamp (green) illuminates :RED ON Key warning lamp (red) illuminates :BLUE IND Key warning lamp (green) flashes :RED IND Key warning lamp (red) flashes |