WCS-20 < COMPONENT DIAGNOSIS > METER BUZZER CIRCUIT METER BUZZER CIRCUIT Description INFOID:0000000000964491 • The buzzer for warning chime system is installed in the combination meter. Component Function Check INFOID:0000000000964492 1. CHECK OPERATION OF METER BUZZER 1. Select “BUZZER” of “BCM” on CONSULT-III. 2. Perform “LIGHT WARN ALM” of “ACTIVE TEST”. Does meter buzzer beep? YES >> INSPECTION END NO >> GO TO 2. 2. CHECK UNIFIED METER AND A/C AMP. INPUT SIGNAL Select the “Data Monitor” for the “METER/M&A” and check the “BUZZER” monitor value. Is the inspection result normal? YES >> Replace combination meter. NO >> Replace BCM. Refer to BCS-79, "Removal and Installation" Diagnosis Procedure INFOID:0000000000964493 1. CHECK POWER SUPPLY OF COMBINATION METER Check power supply of combination meter. Refer to WCS-17, "COMBINATION METER : Diagnosis Proce- . Is the inspection result normal? YES >> GO TO 2. NO >> Repair power supply circuit of combination meter. 2. CHECK BATTERY POWER SUPPLY OF UNIFIED METER AND A/C AMP. Check battery power supply of unified meter and A/C amp. Refer to WCS-17, "UNIFIED METER AND A/C . Is the inspection result normal? YES >> INSPECTION END NO >> Repair power supply circuit of unified meter and A/C amp. BUZZER Under the condition of buzzer input : ON Except above : OFF |