HFC-134a (R-134a) Service Procedure

NCHA0159

SETTING OF SERVICE TOOLS AND EQUIPMENT

NCHA0159S01

Discharging Refrigerant

NCHA0159S0101

WARNING:

Avoid breathing A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose and
throat. Remove HFC-134a (R-134a) from A/C system using certified service equipment meeting require-
ments of SAE J2210 (R-134a recycling equipment) or J2209 (R-134a recovery equipment). If acciden-
tal system discharge occurs, ventilate work area before resuming service. Additional health and safety
information may be obtained from refrigerant and lubricant manufacturers.

SHA179FA

Evacuating System and Charging Refrigerant

NCHA0159S0102

SHA180FA

GI

MA

EM

LC

EC

FE

CL

MT

AT

AX

SU

BR

ST

RS

BT

SC

EL

IDX

SERVICE PROCEDURE

MANUAL

HFC-134a (R-134a) Service Procedure

HA-191

SHA251FA

*1: HA-193
*2: HA-204

*3: HA-206
*4: HA-183

*5: HA-124

SERVICE PROCEDURE

MANUAL

HFC-134a (R-134a) Service Procedure (Cont’d)

HA-192

Maintenance of Lubricant Quantity in
Compressor

NCHA0160

The lubricant in the compressor circulates through the system with
the refrigerant. Add lubricant to compressor when replacing any
component or after a large gas leakage occurred. It is important to
maintain the specified amount.
If lubricant quantity is not maintained properly, the following mal-
functions may result:

I

Lack of lubricant: May lead to a seized compressor

I

Excessive lubricant: Inadequate cooling (thermal exchange
interference)

LUBRICANT

NCHA0160S01

Name: Nissan A/C System Oil Type R
Part number: KLH00-PAGR0

CHECKING AND ADJUSTING

NCHA0160S02

Adjust the lubricant quantity according to the test group shown
below.

1

LUBRICANT RETURN OPERATION

Can lubricant return operation be performed?

I

A/C system works properly.

I

There is no evidence of a large amount of lubricant leakage.

Yes or No

Yes

©

GO TO 2.

No

©

GO TO 3.

2

PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS

1. Start engine, and set the following conditions:

I

Test condition
Engine speed: Idling to 1,200 rpm
A/C or AUTO switch: ON
Blower speed: Max. position
Temp. control: Optional [Set so that intake air temperature is 25 to 30°C (77 to 86°F).]

2. Perform lubricant return operation for about 10 minutes.
3. Stop engine.

CAUTION:

If excessive lubricant leakage is noted, do not perform the lubricant return operation.

©

GO TO 3.

3

CHECK COMPRESSOR

Should the compressor be replaced?

Yes or No

Yes

©

GO TO HA-195.

No

©

GO TO 4.

GI

MA

EM

LC

EC

FE

CL

MT

AT

AX

SU

BR

ST

RS

BT

SC

EL

IDX

SERVICE PROCEDURE

MANUAL

Maintenance of Lubricant Quantity in Compressor

HA-193

4

CHECK ANY PART

Is there any part to be replaced? (Evaporator, condenser, liquid tank or in case there is evidence of a large amount of
lubricant leakage.)

Yes or No

Yes

©

GO TO HA-195.

No

©

Carry out the A/C performance test.

SERVICE PROCEDURE

MANUAL

Maintenance of Lubricant Quantity in Compressor (Cont’d)

HA-194

 

 

 

 

 

 

 