Symptom:

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR SHORT
TO VOLTAGE

When Monitored and Set Condition:

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR SHORT TO VOLT-
AGE

When Monitored:

At all times when battery power is supplied to the Instrument Cluster.

Set Condition:

When the Instrument Cluster senses voltage to the driver door lock switch

above 4.85 volts.

POSSIBLE CAUSES

DTC PRESENT

INSTRUMENT CLUSTER - DRIVER DOOR LOCK SWITCH VOLTAGE LOW

DOOR LOCK SWITCH GROUND OPEN

DRIVER DOOR LOCK SWITCH MUX WIRE SHORT TO VOLTAGE

INSTRUMENT CLUSTER - VOLTAGE TO HIGH

DRIVER DOOR LOCK SWITCH MUX CIRCUIT OPEN

DOOR LOCK SWITCH - SHORT TO VOLTAGE

DOOR LOCK SWITCH OPEN

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Cycle the ignition switch from ON to OFF.
With the DRBIII

t, read DTC’s.

Operate the door locks from the Driver Door Lock Switch while monitoring the
DRBIII

t.

Does the DRBIII

t display DRV DOOR LOCK SW INPUT OPEN?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Check for any possible loose connections at
the instrument cluster and the door lock switch.
Perform BODY VERIFICATION TEST - VER 1.

2

With the DRBIII

t in Sensors, read the DR DOOR LOCK SW voltage.

Voltage reading is:.

All

Above 5.2 volts

Go To

3

Between 4.9 and 5.1 volts

Go To

5

Below 4.8 volts

Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.

469

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

3

Disconnect the Instrument Cluster C2 connector.
Measure the voltage between Driver Door Lock Switch Mux circuit and ground.
Is there any voltage present?

All

Yes

→ Go To 4

No

→ Replace the Instrument Cluster.

Perform BODY VERIFICATION TEST - VER 1.

4

Disconnect the Driver Door Lock Switch (Driver Door Module C1) connector.
Disconnect the Instrument Cluster C2 connector.
Measure the voltage between Driver Door Lock Switch Mux circuit and ground.
Is there any voltage present?

All

Yes

→ Repair the Driver Door Lock Switch Mux circuit for a short to

voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Door Lock Switch.

Perform BODY VERIFICATION TEST - VER 1.

5

Disconnect the Driver Door Lock Switch (Driver Door Module C1) connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?

All

Yes

→ Go To 6

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

6

Disconnect the Driver Door Lock Switch (Driver Door Module C1) connector.
Measure the voltage between Driver Door Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?

All

Yes

→ Go To 7

No

→ Repair the Driver Door Lock Switch Mux circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

7

If there are no possible causes remaining, view repair.

All

Repair

Replace the Driver Door Module..
Perform BODY VERIFICATION TEST - VER 1.

470

POWER DOOR LOCKS/RKE

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR SHORT TO
VOLTAGE —

Continued

Symptom:

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT SHORTED

When Monitored and Set Condition:

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT SHORTED

When Monitored:

At all times when battery power is supplied to the Instrument Cluster.

Set Condition:

When the Instrument Cluster senses voltage to the driver door lock switch

below .25 volts, the input circuit is not valid and this code will set.

POSSIBLE CAUSES

DTC PRESENT

DOOR LOCK SWITCH SHORTED

DOOR LOCK SWITCH MUX SHORTED

INSTRUMENT CLUSTER - - DRIVER DOOR LOCK SWITCH INPUT SHORTED

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTC’s.

Operate the door locks several times from the Driver Door Lock Switch while
monitoring the DRBIII

t.

Does the DRBIII

t display DR DOOR LOCK SW INPUT CIRCUIT SHORTED?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.

2

Disconnect the Driver Door Lock Switch (Driver Door Module C1) connector.
With the DRBIII

t in sensors, read the DRV DOOR LOCK SW MUX circuit.

Is the voltage above 4.6 volts?

All

Yes

→ Replace the Driver Door Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

3

Disconnect the Driver Door Lock Switch (Driver Door Module C1) connector.
Disconnect the Instrument Cluster C2. connector.
Measure the resistance between Driver Door Lock Switch Mux circuit and ground.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Driver Door Lock Switch Mux circuit for a short to

ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

471

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

If there are no possible causes remaining, view repair.

All

Repair

Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.

472

POWER DOOR LOCKS/RKE

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT SHORTED —

Continued

 

 

 

 

 

 

 