DAF CF65, CF75, CF85 Series . Manual - part 579

 

  Index      DAF     DAF CF65, CF75, CF85 Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  577  578  579  580   ..

 

 

DAF CF65, CF75, CF85 Series . Manual - part 579

 

 

10

E501714

M

31

30B

1000

B200

DL

DO

DO

DL

1

3

C774

7

I
I

I

Initial

position:

door

unlocked

-

The

door

is

locked

using

the

button/key

.

The

top

switch

is

directly

switched

over

via

the

rod

linkage.

As

a

result,

a

current

will

flow

through

the

fuse,

connection

30B,

the

motor

,the

bottom

switch

and

the

top

switch

through

connection

31

to

earth.

B

ecause

of

the

mechanical

connection

between

the

m

otor

and

the

locking

button,

the

button

m

oves

downwards.

W

hen

the

lower

position

is

reached,

th

e

‘end

st

roke’

swit

ch

(t

he

lower

swit

ch

in

th

e

diagram)

switches

over

.T

he

forces

are

transmitted

from

the

motor

to

the

locking

button

via

a

crank/connecting

rod

linkage.

-

The

door

is

locked

using

switch

C

774.

When

spring-loaded

switch

C774

makes

a

connection

between

connections

3

and

7,

connection

point

DL

of

B200

is

connected

to

earth.

A

s

a

result,

a

current

will

flow

through

the

fuse,

connection

30B,

the

motor

and

the

bottom

switch

to

earth.

A

brief

moment

is

suf

ficient

to

start

the

motor

.Since

there

is

a

mechanical

connection

between

the

m

otor

and

the

locking

button,

the

top

switch

will

switch

over

immediately

.A

current

will

pass

until

the

‘end

stroke’

switch

interrupts

the

circuit.

200404

2-156

5

ELECTRICAL SYSTEM

Electrical system

CF65/75/85 series ≥0E621376

10

E501715

M

31

30B

1000

B200

DL

DO

DO

DL

1

3

C774

7

I
I

I

Initial

position:

door

locked

-

The

door

is

unlocked

using

the

button/key

.

The

top

switch

is

directly

switched

over

via

the

rod

linkage.

As

a

result,

a

current

will

flow

through

the

fuse,

connection

30B,

the

motor

,the

bottom

switch

and

the

top

switch

through

connection

31

to

earth.

B

ecause

of

the

mechanical

connection

between

the

m

otor

and

the

locking

button,

the

button

m

oves

upwards.

When

the

lower

position

is

reached,

the

‘end

stroke’

switch

(the

lower

switch

in

the

diagram)

switches

over

.T

he

forces

are

transmitted

from

the

m

otor

to

the

locking

button

via

a

crank/connecting

rod

linkage.

-

The

door

is

unlocked

using

switch

C

774.

When

spring-loaded

switch

C774

makes

a

connection

between

connections

3

and

1,

connection

point

DO

of

B200

is

connected

to

earth.

A

s

a

result,

a

current

will

flow

through

the

fuse,

connection

30B,

the

motor

and

the

bottom

switch

to

earth.

A

brief

moment

is

suf

ficient

to

start

the

motor

.Since

there

is

a

mechanical

connection

between

the

m

otor

and

the

locking

button,

the

top

switch

will

switch

over

immediately

.A

current

will

pass

until

the

‘end

stroke’

switch

interrupts

the

circuit.

200404

2-157

Electrical system

5

ELECTRICAL SYSTEM

CF65/75/85 series ≥0E621376

10

CENTRAL

DOOR

LOCKING

(CDS

-3

)

SEE

THE

SYSTEM

MANUAL

FOR

M

ORE

INFORMA

T

ION

SH

CAB

ROOF

HA

TCH

OPENING

R

OOF

HA

TCH

When

the

roof

hatch

switch

(C736)

is

operated

and

a

connection

is

made

between

contacts

2

and

6

and

therefore

between

contacts

1

and

3,

a

voltage

is

applied

to

pin

1

of

the

roof

hatch

motor

(B175)

through

fuse

E028,

switch

C736

and

wire

4761.

The

roof

hatch

will

open.

CLOSING

R

OOF

HA

TCH

When

the

roof

hatch

switch

(C736)

is

operated

and

a

connection

is

made

between

contacts

8

and

6

and

therefore

between

contacts

7

and

3,

a

voltage

is

applied

to

pin

2

of

the

roof

hatch

motor

(B175)

through

fuse

E028,

switch

C736

and

wire

4760.

The

roof

hatch

will

now

close.

VARIANTS

Location 36

If

the

standard

version

is

installed,

the

m

otor

for

door

locking

on

the

driver

’s

side

(B199)

and

the

electronic

unit

for

central

door

locking

(D905)

are

not

fitted.

The

connections

on

B200

are

as

follows:

Connection point

Wi

re

number:

Description

1

1105

Power

supply

2

5061

Open

door

3

5062

Close

door

4

M

Earth

Wire

5062

is

directly

connected

to

connection

point

7

of

switch

C

774.

200404

2-158

5

ELECTRICAL SYSTEM

Electrical system

CF65/75/85 series ≥0E621376

10

37

1358030/26

EL001356

1

23456789

1

0

1

1

1

2

1

3

1

4

1

5

1

6

1

7

1

8

1

9

2

0

2

1

2

2

2

3

2

4

2

5

2

6

2

7

2

8

2

9

3

0

3

1

3

2

3

3

3

4

3

5

3

6

3

7

3

8

3

9

4

0

4

1

4

2

4

3

4

4

4

5

4

6

4

7

4

8

4

9

5

0

5

1

5

2

5

3

1107

1107

1101

1101

1107

1107

1107

4537

4537

4538

4537

5062

5062

5062

4538

4538

3646

3646

3646

3647

3647

3647

5118

5118

5118

5061

5061

5061

5061

5061

5061

3647

3646

3646

3647

1101

1101

1101

1101

1101

1101

1101

4761

4760

4706

4761

4760

4706

4706

4761

4760

1107

4706

1107

1101

D929

1010

1000

1010

1000

E028

15A

E084

10A

B175

M

4

2

1

3

30B

DL

31

B199

1

3

4

DO

2

M

DL

31

DO

B200

3

4

2

30B

1

M

0

C774

3

71

II

I

A021

8

D911

B15/

604

B16/

604

D900

C13/

594

15/403

1

570

3

571

9

571

2

571

7

571

17

554

16

554

18

554

20

554

21

570

1

640

1

641

C735

5

17

14/403

1

571

15

555

10

553

11

591

18

555

16

555

11

553

1

553

1

555

11

555

10

574

12

555

19

574

19

555

18

570

13/

600

15/

600

8/

600

10/

600

2/

600

16/

600

D905

12/

600

3/

600

14/

600

17

555

10

591

17

570

0

3

71

82

6

II

I

C736

1

591

200404

2-159

Electrical system

5

ELECTRICAL SYSTEM

CF65/75/85 series ≥0E621376

 

 

 

 

 

 

 

Content   ..  577  578  579  580   ..