10 12 REVERSING LIGHTS When contact has been made, power is supplied to the operating switch of the reversing lights (E592) via E 016 and wire 1217. This switch is mounted in the gearbox. T he contacts are closed w hen the gearbox is set to the “reverse” position. The voltage is then applied to earth through fuse E016, wire 1217, connection point 1 of G350 (reversing light relay), w ire 5655, contacts 1 and 2 of switch E 592. If relay G 350 is activated, a voltage is applied to the reversing lights (C026 and C027) via wire 4591. At the same time the reversing buzzer (B176) is activated and the voltage is also applied to the drawn vehicle connector A000 (pin 3) or to A070 (pin 4). The above description applies to vehicle ty pe FA . VARIANTS Location 9, 10 Connector 626 for a manual gearbox. Connector 868 for an A S Tr onic gearbox. Connector 644 for an Allison gearbox. 12 -> 38 Only for vehicle type FA. 39 -> 51 Only for vehicle type F T. 18, 24, 31 Connector 873: only for vehicle ty pe FA . 19, 27 Fit w ires 4591 and 6012 in connector 584. 24, 27 Connector 877 : only if the vehicle has a buf fer beam as standard. 32, 45 Depending on whether the ve hi cl ei sf itt edw itha7 -p in or 15-pin plug. See also section diagram 47or 48. 200404 2-76 5 ELECTRICAL SYSTEM Electrical system CF65/75/85 series ≥0E621376 |