© 2-1 Explanatory notes to ALS-S fault codes ALS-S DAVIE XD diagnostics manual 16 2. EXPLANATORY NOTES TO ALS-S FAULT CODES 2.1 EXPLANATORY NOTES TO ALS-S FAULT CODES Fault code Fault code description with possible cause Symptom 17-19 Internal fault in VIC unit due to: - short circuit to supply on pin B16 of the ALS-S unit - Incorrect or no actuation of hazard warning lights - Alarm system cannot be activated 17-20 No signal to siren due to: - short circuit to earth on pin B3 of the ALS-S unit - Alarm system cannot be activated 17-98 Interruption of power supply to ALS-S unit due to: - faulty fuse E023 - short circuit to earth on pin A2 of the ALS-S unit - Alarm system cannot be activated - Alarm signal after closing doors with remote control - Interior detection cannot be deactivated - Loadspace detection cannot be deactivated - No read-out on LED unit - No alarm signal when tilting the cab 33-81 Siren backup battery discharged due to: - internal fault - No siren signal 33-97 Interruption of power supply to siren due to: - interruption on pin 2 (B338) of siren - Alarm signal when closing doors with remote control 33-113 No siren signal due to: - internal fault in siren unit B388 - No siren signal 49-65 No interior detection due to: - internal fault in ultrasonic unit D909 - internal fault in ultrasonic sensor D604 (receiver) - internal fault in ultrasonic sensor D605 (transmitter) - No alarm signal by interior detection 65-49 No loadspace detection due to: - short circuit to earth on pin B4 of the ALS-S unit - short circuit to supply on pin B4 of the ALS-S unit - interruption on pin B4 of the ALS-S unit - No alarm signal by loadspace detection 97-49 No alarm signal from cab locking sensor due to: - interruption on pin B5 of the ALS-S unit - short circuit to supply on pin B5 of the ALS-S unit - No alarm signal by cab locking sensor 99-49 No loadspace detection due to: - short circuit to supply on pin B6 of the ALS-S unit - interruption on pin B6 of the ALS-S unit - No alarm signal by loadspace detection 100-49 No alarm signal by driver's side door switch: - short circuit to supply on pin B10 of the ALS-S unit - short circuit to supply on pin B11 of the ALS-S unit - No alarm signal when opening doors - Interruption on pin A6 of the ALS-S unit - Alarm signal when closing doors with remote control |