© 1-3 D3LC (ACH-EA) fault codes D3LC (ACH-EA) DAVIE XD diagnostics manual 11 8-1 Short circuit to earth or short circuit to supply on - Cab heater does not start Internal fault in cab heater fan (B305) 8-2 Interruption on pin BM1 and/or BM2 of the ECU, - Cab heater does not start Internal fault in cab heater fan (B305) 8-3 Cab heater fan (B305) speed deviation due to: blocked fan (B305) - missing solenoid in electric motor - defective ECU (D871) - Cab heater fails during operation 9-1 Short circuit to earth or short circuit to supply on - Cab heater does not start 9-2 Interruption on pin A9 and/or A11 of the ECU - Cab heater does not start 10-0 Cab heater gets overheated too often due to: clogged hot air pipes - defective overheating sensor (F627) - insufficient supply of inlet air - Cab heater fails during operation 10-4 ACH-EA safety function switched on as a result too many overheatings - The ECU is blocked 12-1 Short circuit to earth or short circuit to supply on - Cab heater does not start - Cab heater does not switch on or off at the Internal fault in thermostat unit (E566) or timer 12-2 Interruption on pin 10 and/or 11 of the ECU, - Cab heater does not start - Cab heater does not switch on or off at the Internal fault in thermostat unit (E566) or timer 13-1 Short circuit to earth or short circuit to supply on - Cab heater does not start or fails during 13-2 Interruption on pin UF1 and/or UF2 of the ECU, - Cab heater does not start or fails during Fault code Fault code description with possible cause Symptom |