Chrysler Town, Dodge Caravan. Manual - part 884

 

  Index      Chrysler     Chrysler TOWN & COUNTRY, VOYAGER, Dodge Caravan - service repair manual 2001-2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  882  883  884  885   ..

 

 

Chrysler Town, Dodge Caravan. Manual - part 884

 

 

Symptom:

LIFTGATE CYLINDER LOCK SWITCH INPUT STUCK - (EXPORT
ONLY)

When Monitored and Set Condition:

LIFTGATE CYLINDER LOCK SWITCH INPUT STUCK - (EXPORT ONLY)

When Monitored:

At all times when battery power is supplied to the Body Control

Module.

Set Condition:

When the BCM senses voltage to the cylinder lock switch between 1.3 and

3.25 volts for over 10 seconds.

POSSIBLE CAUSES

DTC PRESENT

BODY CONTROL MODULE - LIFTGATE CYLINDER SWITCH VOLTAGE INCORRECT

LIFTGATE CYLINDER SWITCH GROUND OPEN

LIFTGATE CYLINDER LOCK SWITCH MUX OPEN

CYLINDER LOCK SWITCH STUCK

TEST

ACTION

APPLICABILITY

1

NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTC’s.

Remove the key and operate the Liftgate Cylinder Switch several times while
monitoring the DRBIII

t.

Wait 10 seconds.
Does the DRBIII

t display LGATE CYL SW INPUT STUCK?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.

2

With the DRBIII

t in Sensors, read the LGATE CYL LOCK SW voltage.

Does the DRBIII

t display voltage between 1.3 and 3.25 volts?

All

Yes

→ Go To 3

No

→ Replace the Body Control Module.

Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Liftgate Cylinder Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?

All

Yes

→ Go To 4

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

772

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

Disconnect the Liftgate Cylinder Lock Switch connector.
Measure the voltage between Cylinder Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?

All

Yes

→ Go To 5

No

→ Repair the Liftgate Cylinder Lock Switch Mux circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

5

If there are no possible causes remaining, view repair.

All

Repair

Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.

773

POWER DOOR LOCKS/RKE

LIFTGATE CYLINDER LOCK SWITCH INPUT STUCK - (EXPORT ONLY)

Continued

Symptom:

LIFTGATE POWER RELEASE OUTPUT SHORT

When Monitored and Set Condition:

LIFTGATE POWER RELEASE OUTPUT SHORT

When Monitored:

Continuously for non power liftgate vehicles

Set Condition:

When the Body Control Module senses a low output on the Liftgate

Release Driver circuit for longer than 125 ms during a liftgate release actuation.

POSSIBLE CAUSES

DTC PRESENT

BODY CONTROL MODULE - LIFTGATE RELEASE DRIVER SHORTED

LIFTGATE RELEASE DRIVER WIRE SHORT TO GROUND

LIFTGATE RELEASE MOTOR SHORTED

TEST

ACTION

APPLICABILITY

1

Ensure vehicle is unlocked before proceeding.
Turn the ignition on.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTC’s.

Operate the Liftgate Release several times from the Liftgate Handle Switch while
monitoring the DRBIII

t.

Does the DRBIII

t display LIFTGATE POWER RELEASE OUTPUT SHORT?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.

2

Disconnect the Body Control Module C3 connector.
Measure the resistance between ground and the Liftgate Release Driver circuit.
Is the resistance below 3.5 ohms?

All

Yes

→ Go To 3

No

→ Disconnect the BCM harness connector(s). Check connectors -

Clean/repair as necessary. If okay, replace the Body Control
Module.
Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Liftgate Ajar Switch connector.
Disconnect the Body Control Module C3 connector.
NOTE: Check connectors - Clean/repair as necessary.
Measure the resistance between Liftgate Release Driver circuit and ground.
Is the resistance below 100.0 ohms?

All

Yes

→ Repair the Liftgate Release Driver circuit for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

774

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

If there are no possible causes remaining, view repair.

All

Repair

Replace the Liftgate Release Motor.
Perform BODY VERIFICATION TEST - VER 1.

775

POWER DOOR LOCKS/RKE

LIFTGATE POWER RELEASE OUTPUT SHORT —

Continued

 

 

 

 

 

 

 

Content   ..  882  883  884  885   ..