Chrysler 300/300 Touring/300C, Dodge Magnum. Manual - part 2244

 

  Index      Chrysler     Chrysler 300/300 Touring/300C, Dodge Magnum - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  2242  2243  2244  2245   ..

 

 

Chrysler 300/300 Touring/300C, Dodge Magnum. Manual - part 2244

 

 

71, or 72?

Yes

>> As present, diagnose and repair the faults in the following order: DTC 72 first, then DTC 62, then DTC

61, then DTCs 64, 68, or 71, then DTCs 63, 67, or 69, and finally DTCs 41, 43, or 44. Refer to the
Table Of Contents in this section for a complete list of HVAC related symptoms.

No

>> Go To 2

2.

INSPECT ACTUATOR & HOUSING ASSEMBLY FOR A CONDITION CAUSING THE LEFT BLEND DOOR TO
BIND

Turn the ignition off.

Inspect the actuator, linkage, and housing assembly for a condition causing the left blend door to bind.

Are there any physical or mechanical problems with the door, housing, linkage, or actuator?

Yes

>> Repair as necessary in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

No

>> Go To 3

3.

CHECK LEFT BLEND DOOR TRAVEL

Remove the Left Blend Door Actuator from the A/C Heater Housing Assembly.

By hand, attempt to rotate the door in both directions. The door should operate smoothly in both directions over the
entire span of travel (approximately 190 degrees).

Does the door operate smoothly in both directions over the entire span of travel?

Yes

>> Replace the Left Blend Door Actuator in accordance with the Service Information. Then, Go To 4.

No

>> Repair as necessary in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

4.

VERIFY IF THE FAULT IS STILL PRESENT

Turn the ignition on.

Actuate the Clear DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

When the A/C status indicator begins displaying DTCs, set the Mode switch to the floor position, simulta-
neously press the A/C mode switch and the EBL mode switch down until both LEDs start flashing (approxi-
mately 5 seconds) and then release the mode switches. Stored DTCs will clear from memory in approximately
two seconds.

Turn the ignition off, wait 10 seconds, and turn the ignition on.

Actuate the Actuator Circuit Test / Door Calibration Function by performing the following:

Turn the blower control off.

Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL
mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch. While
the test / function is running, the EBL status indicator will flash once per second. If the test / function passes,
the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash
alternately. Allow the test / function to run to completion before proceeding.

Actuate the Display DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

24 - 10

HVAC - ELECTRICAL DIAGNOSTICS

LX

NOTE: The A/C status indicator displays active DTCs when the EBL status indictor is not illuminated and
stored DTCs when the EBL status indicator is illuminated.
Read DTCs from the A/C status indictor.

Does the A/C status indicator display DTC 18?

Yes

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

No

>> Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL

MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

LX

HVAC - ELECTRICAL DIAGNOSTICS

24 - 11

21–BLEND DOOR RANGE TOO LARGE (MTC)

For a complete wiring diagram Refer to Section 8W.

Theory of Operation

NOTE: Diagnose and repair Actuator Circuit Test faults (DTC 61, 62, 63, 64, 67, 68, 69, 71, and 72) before
diagnosing Overcurrent faults (DTC 41, 43, and 44) and Calibration faults (DTC 18, 21, 22, 23, 45, 46, 47, 51,
52, 53, 55, and 56). Diagnose and repair Overcurrent faults (DTC 41, 43, and 44) before diagnosing Calibra-
tion faults (DTC 18, 21, 22, 23, 45, 46, 47, 51, 52, 53, 55, and 56).

The purpose of actuator calibration is to determine the total span of door travel between physical stops. To calibrate
the actuator, the A/C Heater Control first moves the door to its soft stop, and then counts the number of pulses it
takes to move the door to its other stop. An expected range of span is stored in the control’s memory. If the A/C
Heater Control detects too many commutator pulses when calibrating the left blend door, this DTC will set.

When Monitored:
During actuator calibration.

Set Condition:
If the A/C Heater Control detects too many commutator pulses when calibrating the left blend door.

Possible Causes

ACTUATOR CIRCUIT TEST FAULTS PRESENT

OVERCURRENT FAULTS PRESENT

LEFT BLEND DOOR OR A/C HEATER HOUSING COMPONENTS WARPED, WORN, DAMAGED, BROKEN

LEFT BLEND DOOR ACTUATOR

A/C HEATER CONTROL

Diagnostic Test

1.

VERIFY IF ANY ACTUATOR CIRCUIT TEST FAULTS OR OVERCURRENT FAULTS ARE PRESENT

Turn the ignition on.

Actuate the Clear DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

When the A/C status indicator begins displaying DTCs, set the Mode switch to the floor position, simulta-
neously press the A/C mode switch and the EBL mode switch down until both LEDs start flashing (approxi-
mately 5 seconds) and then release the mode switches. Stored DTCs will clear from memory in approximately
two seconds.

Turn the ignition off, wait 10 seconds, and turn the ignition on.

Actuate the Actuator Circuit Test / Door Calibration Function by performing the following:

Turn the blower control off.

Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL
mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch. While
the test / function is running, the EBL status indicator will flash once per second. If the test / function passes,
the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash
alternately. Allow the test / function to run to completion before proceeding.

Actuate the Display DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

NOTE: The A/C status indicator displays active DTCs when the EBL status indictor is not illuminated and
stored DTCs when the EBL status indicator is illuminated.
Read DTCs from the A/C status indictor.

Does the A/C status indicator display any of the following DTCs: 41, 43, 44, 61, 62, 63, 64, 67, 68, 69,

24 - 12

HVAC - ELECTRICAL DIAGNOSTICS

LX

71, or 72?

Yes

>> As present, diagnose and repair the faults in the following order: DTC 72 first, then DTC 62, then DTC

61, then DTCs 64, 68, or 71, then DTCs 63, 67, or 69, and finally DTCs 41, 43, or 44. Refer to the
Table Of Contents in this section for a complete list of HVAC related symptoms.

No

>> Go To 2

2.

CHECK FOR A BROKEN LEFT BLEND DOOR ACTUATOR

Turn the ignition off.

Remove the Left Blend Door Actuator from the A/C Heater Housing Assembly.

By hand, attempt to rotate the actuator in both directions.

Does the actuator turn in either direction?

Yes

>> Replace the Left Blend Door Actuator in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

No

>> Go To 3

3.

CHECK THE LEFT BLEND DOOR & A/C HEATER HOUSING FOR WARPED, WORN, & DAMAGED
COMPONENTS

Inspect for excessively worn door linkage and for a damaged or broken A/C Heater Housing Assembly. Inspect for
a warped or broken door, and missing door seals. Rotate the door from stop to stop. The door should rotate approx-
imately 190 degrees.

Are there any physical or mechanical problems with the door or housing?

Yes

>> Repair as necessary in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

No

>> Replace the Left Blend Door Actuator in accordance with the Service Information. Then, Go To 4.

4.

VERIFY IF THE FAULT IS STILL PRESENT

Turn the ignition on.

Actuate the Clear DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

When the A/C status indicator begins displaying DTCs, set the Mode switch to the floor position, simulta-
neously press the A/C mode switch and the EBL mode switch down until both LEDs start flashing (approxi-
mately 5 seconds) and then release the mode switches. Stored DTCs will clear from memory in approximately
two seconds.

Turn the ignition off, wait 10 seconds, and turn the ignition on.

Actuate the Actuator Circuit Test / Door Calibration Function by performing the following:

Turn the blower control off.

Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL
mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch. While
the test / function is running, the EBL status indicator will flash once per second. If the test / function passes,
the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash
alternately. Allow the test / function to run to completion before proceeding.

Actuate the Display DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

LX

HVAC - ELECTRICAL DIAGNOSTICS

24 - 13

 

 

 

 

 

 

 

Content   ..  2242  2243  2244  2245   ..