Chrysler 300/300 Touring/300C, Dodge Magnum. Manual - part 2243

 

  Index      Chrysler     Chrysler 300/300 Touring/300C, Dodge Magnum - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  2241  2242  2243  2244   ..

 

 

Chrysler 300/300 Touring/300C, Dodge Magnum. Manual - part 2243

 

 

12–MODE POT SHORTED (MTC)

For a complete wiring diagram Refer to Section 8W.

When Monitored:
With the ignition on.

Set Condition:
If the mode pot fails the internal self test.

Possible Causes

A/C HEATER CONTROL

NOTE: This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC
is stored. Refer to HVAC System Test (MTC) for stored DTC test procedures.

Diagnostic Test

1.

REPLACE THE A/C HEATER CONTROL

Repair

Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

24 - 6

HVAC - ELECTRICAL DIAGNOSTICS

LX

13–TEMP POT OPEN (MTC)

For a complete wiring diagram Refer to Section 8W.

When Monitored:
With the ignition on.

Set Condition:
If the temp pot fails the internal self test.

Possible Causes

A/C HEATER CONTROL

NOTE: This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC
is stored. Refer to HVAC System Test (MTC) for stored DTC test procedures.

Diagnostic Test

1.

REPLACE THE A/C HEATER CONTROL

Repair

Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

LX

HVAC - ELECTRICAL DIAGNOSTICS

24 - 7

14–TEMP POT SHORTED (MTC)

For a complete wiring diagram Refer to Section 8W.

When Monitored:
With the ignition on.

Set Condition:
If the temp pot fails the internal self test.

Possible Causes

A/C HEATER CONTROL

NOTE: This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC
is stored. Refer to HVAC System Test (MTC) for stored DTC test procedures.

Diagnostic Test

1.

REPLACE THE A/C HEATER CONTROL

Repair

Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES/FRONT CONTROL MODULE - DIAGNOSIS AND TESTING).

24 - 8

HVAC - ELECTRICAL DIAGNOSTICS

LX

18–BLEND DOOR RANGE TOO SMALL (MTC)

For a complete wiring diagram Refer to Section 8W.

Theory of Operation

NOTE: Diagnose and repair Actuator Circuit Test faults (DTC 61, 62, 63, 64, 67, 68, 69, 71, and 72) before
diagnosing Overcurrent faults (DTC 41, 43, and 44) and Calibration faults (DTC 18, 21, 22, 23, 45, 46, 47, 51,
52, 53, 55, and 56). Diagnose and repair Overcurrent faults (DTC 41, 43, and 44) before diagnosing Calibra-
tion faults (DTC 18, 21, 22, 23, 45, 46, 47, 51, 52, 53, 55, and 56).

The purpose of actuator calibration is to determine the total span of door travel between physical stops. To calibrate
the actuator, the A/C Heater Control first moves the door to its soft stop, and then counts the number of pulses it
takes to move the door to its other stop. An expected range of span is stored in the control’s memory. If the A/C
Heater Control detects too few commutator pulses when calibrating the left blend door, this DTC will set.

When Monitored:
During actuator calibration.

Set Condition:
If the A/C Heater Control detects too few commutator pulses when calibrating the left blend door.

Possible Causes

ACTUATOR CIRCUIT TEST FAULTS PRESENT

OVERCURRENT FAULTS PRESENT

LEFT BLEND DOOR BINDING, OBSTRUCTED

LEFT BLEND DOOR ACTUATOR

A/C HEATER CONTROL

Diagnostic Test

1.

VERIFY IF ANY ACTUATOR CIRCUIT TEST FAULTS OR OVERCURRENT FAULTS ARE PRESENT

Turn the ignition on.

Actuate the Clear DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

When the A/C status indicator begins displaying DTCs, set the Mode switch to the floor position, simulta-
neously press the A/C mode switch and the EBL mode switch down until both LEDs start flashing (approxi-
mately 5 seconds) and then release the mode switches. Stored DTCs will clear from memory in approximately
two seconds.

Turn the ignition off, wait 10 seconds, and turn the ignition on.

Actuate the Actuator Circuit Test / Door Calibration Function by performing the following:

Turn the blower control off.

Press and hold the EBL mode switch down and then turn the blower control on. Continue to hold the EBL
mode switch down until the EBL status indicator begins flashing. Then, release the EBL mode switch. While
the test / function is running, the EBL status indicator will flash once per second. If the test / function passes,
the EBL status indicator will stop flashing. If the test / function fails, the A/C and EBL status indicators will flash
alternately. Allow the test / function to run to completion before proceeding.

Actuate the Display DTC function by performing the following:

Turn the blower control on.

Press the A/C mode switch down, turn the blower control to off, wait until both LEDs illuminate (approximately
5 seconds) and then release the A/C mode switch.

NOTE: The A/C status indicator displays active DTCs when the EBL status indictor is not illuminated and
stored DTCs when the EBL status indicator is illuminated.
Read DTCs from the A/C status indictor.

Does the A/C status indicator display any of the following DTCs: 41, 43, 44, 61, 62, 63, 64, 67, 68, 69,

LX

HVAC - ELECTRICAL DIAGNOSTICS

24 - 9

 

 

 

 

 

 

 

Content   ..  2241  2242  2243  2244   ..