15. MEASUREMENT
B-64693EN-1/01
- 2466 - NOTE
The skip signals (SKIP and SKIP2 to SKIP8) are valid regardless of
If you want to use high-speed skip signals when the multi-step skip
#7 SKF Dry run, override, and automatic acceleration/deceleration for G31 skip command 0: Disabled 1: Enabled
CAUTION 1 When bit 7 (SKF) of parameter No.6200 is set to 0, feedrate override, dry run, and automatic acceleration/deceleration are 2 Even if bit 7 (SKF) of parameter No.6200 is set to 1, dry run and automatic acceleration/deceleration are disabled when bit 1 (SFP)
#7 #6 #5 #4 #3 #2 #1 #0 6201
SKPXE
IGX
SEB
[Input type] Parameter input
[Data type] Bit path
#1 SEB When a skip signal, high-speed skip signal or measuring position reached signal goes on while the skip function, the continuous high-speed skip function or the automatic tool Ignored. 1: Considered and compensated. The accumulated pulses and positional deviation due to actual acceleration/deceleration
#4 IGX When the high-speed skip function is used, SKIP, SKIPP, and SKIP2 to SKIP8 are: 0: Enabled as skip signals. 1: Disabled as skip signals.
#7 SKPXE For the skip function (G31), the skip signal SKIP is: 0: Enabled. 1: Disabled.
|