87-135

 

  

   Test 2: A/C system high pressure, checking   

  

  

-  Connect high- and low-pressure hoses of 

refrigerant recovery/ recycling/recharging unit 
Kent-Moore ACR

4

 or equivalent, to high- and 

low-pressure service valves. 

  

  

-  Disconnect electrical connector from coolant 

fan. 

  

  

-  Start engine. 

  

  

-  Set temperature control to maximum "hot" (if 

manual A/C) or "HI" (if Climatronic). 

  

  

-  Manual A/C: Press "A/C" button and select 

highest blower speed. 

  

  

-  Adjust air distribution to footwell outlets. 

  

  

-  Raise engine speed to approximately 1500 

RPM. 

  

   Specified result 

  

   System high pressure is normal if high-pressure 

gauge reads 232 psi (16 bar) within 30 seconds.  

  

   If specified reading is not obtained, also perform 

test 3 and compare results of all three tests 

 

table, 

 

Page 87-137

 .  

A/C refrigerant system, troubleshooting

13/2/2005

87-136

 

  

   Test 3: A/C system low pressure, checking  

  

  

-  Connect high- and low-pressure hoses of 

refrigerant recovery/recycling/recharging unit 
Kent-Moore ACR

4

, or equivalent, to high- and 

low-pressure service valves. 

  

  

-  Start engine. 

  

  

-  Set temperature control to maximum "cold" (if 

manual A/C) or "LO" (if Climatronic). 

  

  

-  Manual A/C: Press "A/C" button and select first 

blower speed. 

  

  

-  Climatronic: Select minimum blower speed 

(manual override)) by pressing "decrease blower 
speed" button (observe blower speed display in 
control head). 

  

  

-  Adjust air distribution to instrument panel 

outlets. 

  

  

-  Raise engine speed to 1500 RPM. 

  

   Specified result 

  

   System low pressure is normal if low-pressure 

gauge reads 22-36 psi (1.5-2.5 bar) within 30 
seconds.  

  

   If specified reading is not obtained, compare 

results of all three tests 

 table, 

 

Page 87-

137

 .  

A/C refrigerant system, troubleshooting

13/2/2005

87-137

 

Test 1  

Temperature 

from center air 

vent

1)

  

Test 2  

High 

pressure

2)

  

Test 3  

Low 

pressure

2)

  

Possible 

causes of 

incorrect 

readings  

Corrective 
measures 
 

Normal  

Normal  

Normal  

None  

---  

Too high  

Normal  

Normal  

Temperature flap 

position 

incorrect  

Adjust temperature 

flap cable  

Too high  

Too low  

Normal  

Compressor  

Replace 

compressor  

Normal  

Too low  

Normal  

Compressor  

Replace 

compressor  

Normal  

Normal  

Too high or 

too low  

  

  

Too high  

Normal  

Too high or 

too low  

Expansion valve 

or compressor  

Clean/replace 

expansion valve or 

replace compressor 

  

Normal  

Too high or 

too low  

Too high or 

too low  

  

  

1)

 Normal air outlet temperature approx. 6 C (43 F). For higher ambient temperatures 

and/or higher humidity, specified air temperature from center instrument panel vent can 
be slightly higher.  

2)

 For normal system temperatures and pressures 

 

Page 87-120

 . 

 

A/C refrigerant system, troubleshooting

13/2/2005

87-138

 

  

  

A/C refrigerant system cooling 
performance, checking 

 

  

   Note:  

  

   Variable displacement A/C compressor maintains 

temperature of 0 C (32 F) in evaporator.  

  

   Test conditions  

  

  

 A/C refrigerant system fully charged 

  

  

 A/C clutch -N25- and compressor function 

OK 

  

  

 Condenser and radiator clean and free of 

obstructions 

  

  

 Air distribution can be adjusted properly  

  

  

 Wiring OK as per wiring diagram 

  

  

 Outside (ambient) temperature 20 C-30 C 

(68 F-86 F) 

A/C refrigerant system, troubleshooting