CD Player and Air Conditioning System-10

Refrigeration of air conditioner failed

Trouble

Descriptions

Analysis of the Cause

1.No pick-up of compressor

1. fuse burned down, compressor’ s relay damaged

2. pressure switch contact disconnected, short circuit or open circuit of the

routing

3. open circuit of clutch’s winding

4. switch burned down

5. master relay burned down

6. slide of the clutch

7. belt of the compressor broke or too loose

8. compressor failure

9. sensor failure(judged by reading the failure code)

10. insufficient cold media, lower systempressure(< 0.97MPa)

11. system pressure above 1.37MPa

12. water temperature of the engine too high

13.V oltage of the clutch below 7V

2. Pick-up of Compressor

1. normally-open contact of the compressor’ s relay stuck and serious leakage

of system cold media, systemrunning short of cold media

2. no wind fromthe blower

Refrigeration

of

air

conditioning

system failed

3. no wind from the blower

1. fuse burned down

2. motor brush of the blower damaged

3. switch of the blower damaged

4. coming off of distribution wire connectors or circuit disconnected

5. speed-adjusting module damaged

6. no wind fromthe blower when at high speed, high-speed relay damaged

Press down “Temp+” switch

Step 11: display “11”(set the temperature zone)

Action of the executor mechanism:
Mode damper: defrost
Circulation damper: external circulation
Temperature damper: cold end
Wind amount: the minimum
Compressor: off

Attention: during the inspection period from step 7 to step 11, the controller will forcibly transit the output signal based on

the code number displayed on the integrated display screen to the functioned executor; the inspection must be done with

such methods as visual inspection, listening to abnormal sound or touching the air vent by hand so as to judge whether

there is any improper operation.

Trouble Diagnosis and Troubleshooting of A i r Conditioning System
Air cooling system

CD Player and Air Conditioning System-11

b .Insufficient refrigeration output

T rouble

Descriptions

Analysis of the Cause

Inadequate

refrigeration

1. wind amount

is normal

1. compressor works normally

(1) low-level pressure at high-pressure and low-pressure sides

a. block of expansion valve

b. openness of expansion valve too narrow

(2) high-level pressure at high-pressure and low-pressure sides

a. failure to high-voltage pipeline, flow not smooth

b. malfunction of thermo resistor

c. openness of expansion valve too wide

d. too much refrigeration oil

e. too much refrigerant

f. poor heat dissipation of the condenser

(3) pressure at high-voltage side too low

a. low-pressure pipeline damaged

b. block of low-pressure pipeline

(4)pressure at low-pressure side too low

a. the evaporator frosted

b. block of expansion valve

c. low-pressure pipeline not smooth

d. malfunction of thermo resistor

(5)pressure at low-pressure side sometime normal, sometimes with negative pressure,

moisture and ice block in air cooling system

(6)negative pressure at low-pressure side, pressure at high-pressure side too low, block of air

cooling system

(7)pressure at low-pressure side too low, pressure at high-pressure side too high

a. internal block of drier of fluid reservoir

b. block of high-pressure pipeline

(8)pressure at low-pressure side too high, pressure at high-pressure side too low

a. leakage of the compressor

b. damaged valve of compressor

(9)poor heat radiation of condenser due to small wind amount fromthe condensing blower

2. compressor works improperly

(1)internal malfunction of compressor

(2)belt of compressor too loose or sliding

(3)failure of electromagnetic clutch

a. low voltage of power supply

b. mutual interference of the stator and rotor

c. malfunction of amplifier stabilizing the idle speed

d. circuit disconnected, coming off of the joints

e. poor operation of the switch and relay

f. short circuit and open circuit of the routing

g. poor earthing

3. other causes

bad sealing of wagon

CD Player and Air Conditioning System-12

e . Precautions for the overhaul of air cooling system

When the air cooling system encounters the trouble, the cause for such trouble shall be analyzed inlightof trouble varieties,

followed with the examination and report work.

c.

T he cooling system sometimes works while sometimes refuses to work.

T rouble

Descriptions

Analysis of the Cause

1. compressor works normally

1. ice block in the cooling system
2. failure of thermal resistor or temperature sensing bulb
3. poor contact of A/C switch
4. condensing blower damaged

T he

cooling

system

sometimes

produces

refrigeration

effect

while

sometimes not.

compressor works improperly

1. slide of the clutch
2. coming off of the clutch’ s winding
3. poor earthing of clutch’ s winding

d.

Noise of the air cooling system

T rouble

Descriptions

A nalysis of the Cause

Noise of the air cooling system too
loud

Noise too loud

(1) belt too loose or worn too much
(2) fastening screw of mounting holder of the compressor

loosened

(3) mounting holder of the compressor damaged
(4) internal parts of the compressor damaged
(5) too much refrigeration oil or none
(6). slide of the clutch
(7). B earing of the clutch running short of oil or damaged
(8). motor bearing of the blower damaged
(9) holder of the blower broken or loosened
(10) blade of the blower broken or loosened
(11). Friction of the blower’ s blade with other components

CD Player and Air Conditioning System-13

1. CC6460K air conditioning system is designed with SD7V16 compressor, whose refrigeration oil type as

specified is SP-10PAG; hence application of other type of refrigeration oil may damage the parts and compo
nents of the compressor. When the air conditioning system goes through maintenance and replacement of
parts, it should be added with new refrigeration oil, whose volume is listed as follows: the evaporator and
condenser: 30ml; the drier: 20ml; the pipeline: 10ml.

     Addition of refrigeration oil can be available with two methods: The direct addition and the vacuum suction

2. Direct addition method

a. remove the oil filler plug and fill with the specified SP-10PAG refrigeration oil.

b. observe through the hole of oil filter plug and rotate front plate of clutch to make the piston connecting rod right position in the

    center of the hole of oil filter plug.

c. insert the dipstick along the right side of piston connecting rod till the top of dipstick touches the case of the compresso r

d. pull out the dipstick and examine the graduations (grooves) of refrigeration oil, the readings shall be within the range of 4-6

    scales.

e. screw firmly the oil filter plug with the fastening torque of 14.7± 4.9N. m

3. Vacuum suction method:

Firstly pump out the refrigerating system to the vacuum of 0.2x105Pa, and then fill with the specified 0.2x10

 5

 Pa refrigeration oil;

the detailed steps are as follows:

a. switch off the high-pressure manual valve and the auxiliary valve.

b. dismantle the high-pressure side hose from the manifold pressure gauge and insert it into the oil cup

c. open the auxiliary valve and have the refrigeration oil sucked into the refrigerating system from the oil cup.

d. when the refrigeration oil in the oil cup is almost pumped out to the vacuum, then immediately turn off the auxiliary valve to

    prevent the air from being sucked into the system.

e. secure the hose adapter at high-pressure side to the manifold pressure gauge, start the vacuum pump and turn on the high-

   pressure manual valve, then turn on the auxiliary valve to pump the system to the vacuum state of 0.2x10

5

Pa, keep such state

   for 15mins so as to discharge out the air flowing into the system along with the oil.

Volume of Refrigeration Oil Addition and its Methods

2.air heating system

T rouble

C auses of the trouble

Heating not supplied or
not sufficiently supplied

1. blower of air conditioner failure 2. relay of the blower damaged
3. heating water pipe blocked

4. cooling water pipe blocked

5. cold/hot damper executor damaged 6. insufficient cooling liquid

No rotation of blower

1. fuse burned down or poor contact of the switch
2. motor of the blower burned down
3. open circuit of high-speed relay of the blower
4. speed-adjusting module damaged
5. short circuit

leakage of water

W ater pipe of air heating aged, insecure joint

Overheat

1. speed-adjusting resistor of the fan damaged
2. cold/hot damper executor damaged

Insufficient hot air
volume for defrosting

1. mode executor damaged
2. falling off of the drive rod
3. damper not in position
4. air vent blocked
5. inadequate heating supply
6. installation of wind tunnel not fit
7. circuit disconnected

 

 

 

 

 

 

 