Great Wall Hover. Manual - part 88

 

  Index      Great Wall     Great Wall Hover - service repair manual

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  86  87  88  89   ..

 

 

Great Wall Hover. Manual - part 88

 

 

CD Player and Air Conditioning System-6

Turn the ignition switch from OFF to ON

The display symbols all light up

failure of the switch or display tune

NO

Press down “Temp+”  switch

Enter into self-diagnosis procedur1?

NO

“ Temp +” switch failure

Step 1: Display “01”

(set the temperature zone)

all other display symbols turn off

Press down “Temp+” switch

Step 2: Display “02”(set  the
temperature zone)

The inspection procedures

During the period of 10 seconds after the engine is started(turn the ignition switch from OFF to ON), press OF F, A U TO,
RR and MODE once more, and the pressing of MODE switch shall last at least 2 seconds .

All sensors are good.

Display “000”(outsidetemperature)

 

CD Player and Air Conditioning System-7

Code of failure

Sensor failure

100

Open circuit of outside temperature sensor

200

Short circuit of outside temperature sensor

010

Open circuit of inside temperature sensor

020

short circuit of inside temperature sensor

001

Open circuit of temperature sensor of the evaporator

002

Short circuit of temperature sensor of the evaporator

Step 3: Display “03”(set the temperature zone)

Display the outside temperature value

Press down “Temp+” switch

Step 4: Display “04”(set the temperature zone)

Sensor failure

The code of the sensor with failure
is showed on   the display screen.

Press down “Temp+” switch

Press down “Temp+” switch

Step 5: Display “05”

(set the temperature zone)

          

Display the inside temperature value

Display the temperature value of the evaporator

Press down “Temp+” switch

 

 

 

 

 

 

 

 

 

 

 

 

 

CD Player and Air Conditioning System-8

Step 6: Display “06”(set the temperature zone)

Press down “Temp+” switch

Display the detection code of mode/
temperature damper executor

Press down “Temp+” switch

Step 7: display “07”(set the temperature zone)

Action of the executor mechanism:
Mode damper: wind to the person
Circulation damper: internal circulation
Temperature damper: cold end
Wind amount: the maximum
Compressor: enabled

Note: X is a digital number without specific meaning; the code
number is displayed in the outside temperature display zone.

 display “08”

C

 

Code number 

Code Meaning 

0x0 

Temperature damper executor works normally 

0x1 

Detection for temperature damper executor is in progress. 

0x2 

Temperature damper executor failure 

00x 

Mode damper executor works normally 

01x 

Detection for mode damper executor is in progress. 

02x 

Mode damper executor failure 

 

 

 

 

 

 

 

CD Player and Air Conditioning System-9

Step 9: display “09”

Action of the executor mechanism:
Mode damper: wind to the person and the fee
Circulation damper: internal circulation
Temperature damper: in the middle
Wind amount: bigger
Compressor: enabled

Action of the executor mechanism:
Mode damper: wind to the feet and defrost
Circulation damper: external circulation
Temperature damper: in the middle Wind amount: small
Compressor: off

display “10”(set the temperature zone)

Action of the executor mechanism:
Mode damper: wind to the person and the feet
Circulation damper: external circulation
Temperature damper: hot end
Wind amount: medium
Compressor: enabled

Press down “Temp+” switch

Press down “Temp+” switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Content   ..  86  87  88  89   ..