TEST ACTION APPLICABILITY 3 Disconnect the Instrument Cluster C2 connector. All Yes → Go To 4 No → Replace the Instrument Cluster. Perform BODY VERIFICATION TEST - VER 1. 4 Disconnect the Passenger Door Lock Switch connector. All Yes → Repair the Passenger Door Lock Switch Mux circuit for a short to voltage. No → Test Complete. 5 Disconnect the Passenger Door Lock Switch connector. All Yes → Go To 6 No → Repair the Ground circuit for an open. Perform BODY VERIFICATION TEST - VER 1. 6 Disconnect the Passenger Door Lock Switch connector. All Yes → Go To 7 No → Repair the Passenger Door Lock Switch Mux circuit for an open. Perform BODY VERIFICATION TEST - VER 1. 7 If there are no possible causes remaining, view repair. All Repair Replace the Door Lock Switch. 477 POWER DOOR LOCKS/RKE PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR SHORT Continued |