Dodge Ram. Manual - part 119

 

  Index      Dodge     Dodge Ram - service manual 2004 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  117  118  119  120   ..

 

 

Dodge Ram. Manual - part 119

 

 

Symptom:

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT STUCK

When Monitored and Set Condition:

DRIVER DOOR LOCK SWITCH INPUT CIRCUIT STUCK

When Monitored:

At all times when battery power is supplied to the Instrument Cluster.

Set Condition:

When the instrument cluster senses voltage to the driver door lock switch

between 1.3 and 3.75 for over 20 seconds, this code will set.

POSSIBLE CAUSES

DTC PRESENT

INSTRUMENT CLUSTER - DOOR LOCK SWITCH VOLTAGE INCORRECT

DOOR LOCK SWITCH MUX CIRCUIT PARTIAL SHORT TO GROUND

DOOR LOCK SWITCH STUCK

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTC’s.

Operate the door lock several times from the Driver Door Lock Switch while
monitoring the DRBIII

t.

Does the DRBIII

t display DR DOOR LOCK SW INPUT STUCK?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Check the door lock switch for a possible
intermittent sticking condition
Perform BODY VERIFICATION TEST - VER 1.

2

With the DRBIII

t in Sensors, read the DR DOOR LOCK SW voltage.

Does the DRBIII

t display voltage between 1.3 and 3.75 volts?

All

Yes

→ Go To 3

No

→ Replace the Instrument Cluster.

Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Driver Door Lock Switch (Driver Door Module C1) connector.
Measure the voltage between Door Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?

All

Yes

→ Replace the Driver Door Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Driver Door Lock Switch Mux circuit for a partial short

to ground.
Perform BODY VERIFICATION TEST - VER 1.

473

POWER DOOR LOCKS/RKE

Symptom:

DRIVER DOOR UNLOCK OUTPUT CIRCUIT SHORT TO GROUND
OR VOLTAGE

When Monitored and Set Condition:

DRIVER DOOR UNLOCK OUTPUT CIRCUIT SHORT TO GROUND OR VOLTAGE

When Monitored:

Whenever the instrument cluster is awake.

Set Condition:

The instrument cluster monitors the driver door unlock output circuit and

when it is shorted to ground or to voltage, this code will set. This code will only set when
the door locks are actuated.

POSSIBLE CAUSES

DTC PRESENT

DOOR UNLOCK DRIVER LEFT FRONT WIRE SHORTED TO GROUND

DOOR LOCK DRIVER LEFT DOORS SHORTED TO DOOR UNLOCK DRIVER LEFT FRONT

DOOR LOCK DRIVER LEFT DOORS WIRE SHORTED TO GROUND

DOOR UNLOCK DRIVER LEFT FRONT CIRCUIT SHORTED TO VOLTAGE

DRIVER DOOR LOCK MOTOR SHORT TO GROUND

INSTRUMENT CLUSTER - SHORTED

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Cycle the ignition switch from ON to OFF.
With the DRBIII

t, read DTC’s.

Operate the door locks several times from a door lock switch while monitoring the
DRBIII

t.

Does the DRBIII

t display DRIVER DOOR UNLOCK OUTPUT SHT GROUND OR

VOLTAGE?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Check for any possible shorted conditions
between the instrument cluster and the Driver door lock motor.
Perform BODY VERIFICATION TEST - VER 1.

2

Turn the ignition off.
Disconnect the Instrument Cluster C1 connector.
Measure the resistance between the Door Unlock Driver Left Front circuit and the
Door Lock Driver Left Doors circuit in the Instrument Cluster connector.
Is the resistance below 3.0 ohms?

All

Yes

→ Repair the Door Lock Driver Left Doors circuit for a short to the

Door Unlock Driver Left Front circuit (could be a shorted motor).
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

474

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the Instrument Cluster C1 connector.
Measure the resistance between ground and the Door Unlock Driver Left Front
circuit in the Instrument Cluster C1 connector.
Is the resistance below 1000.0 ohms?

All

Yes

→ Go To 4

No

→ Go To 7

4

Turn the ignition off.
Disconnect the Instrument Cluster C1 connector.
Disconnect the Driver Door Lock Motor connector.
Measure the resistance between ground and the Door Unlock Driver Left Front
circuit in the Instrument Cluster connector.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Unlock Driver Left Front wire for a short to

ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Turn the ignition off.
Disconnect the Instrument Cluster C1 connector.
Disconnect the Driver Door Lock Motor connector.
Measure the resistance between ground and the Door Lock Driver Left Doors circuit
in the Instrument Cluster connector.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Lock Driver Left Doors wire for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 6

6

If there are no possible causes remaining, view repair.

All

Repair

Replace the Driver Door Lock Motor.
Perform BODY VERIFICATION TEST - VER 1.

7

Disconnect the Instrument Cluster C1 connector.
Turn the ignition on.
Measure the voltage between ground and the Door Unlock Driver Left Front circuit.
Is there any voltage present?

All

Yes

→ Repair the Door Unlock Driver Left Front or Door Lock Driver

Left Doors circuit for a short to voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 8

8

If there are no possible causes remaining, view repair.

All

Repair

Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.

475

POWER DOOR LOCKS/RKE

DRIVER DOOR UNLOCK OUTPUT CIRCUIT SHORT TO GROUND OR
VOLTAGE —

Continued

Symptom:

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR
SHORT TO VOLTAGE

When Monitored and Set Condition:

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR SHORT TO
VOLTAGE

When Monitored:

At all times when battery power is supplied to the Instrument Cluster.

Set Condition:

When the Instrument Cluster senses voltage to the passenger door lock

switch above 4.85 volts this code will set and the input will not be valid..

POSSIBLE CAUSES

DTC PRESENT

INSTRUMENT CLUSTER - PASSENGER DOOR LOCK SWITCH VOLTAGE LOW

DOOR LOCK SWITCH GROUND OPEN

INSTRUMENT CLUSTER - VOLTAGE TO HIGH

PASSENGER DOOR LOCK SWITCH MUX WIRE SHORT TO VOLTAGE

PASSENGER DOOR LOCK SWITCH MUX CIRCUIT OPEN

DOOR LOCK SWITCH - SHORT TO VOLTAGE

DOOR LOCK SWITCH OPEN

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Cycle the ignition switch from ON to OFF.
With the DRBIII

t, read DTC’s.

Operate the door locks from the Passenger Door Lock Switch while monitoring the
DRBIII

t.

Does the DRBIII

t display PASS DOOR LOCK SW INPUT OPEN?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Check for any possible loose connections at
the instrument cluster and the door lock switch.
Perform BODY VERIFICATION TEST - VER 1.

2

With the DRBIII

t in Sensors, read the PASS DOOR LOCK SW MUX voltage.

Voltage reading is:.

All

Above 5.2 volts

Go To

3

Between 4.9 and 5.1 volts

Go To

5

Below 4.8 volts

Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.

476

POWER DOOR LOCKS/RKE

 

 

 

 

 

 

 

Content   ..  117  118  119  120   ..