Dodge Dakota (R1). Manual - part 52

 

  Index      Dodge     Dodge Dakota (R1) - service repair manual 2000 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  50  51  52  53   ..

 

 

Dodge Dakota (R1). Manual - part 52

 

 

TEST

ACTION

APPLICABILITY

7

NOTE: Ensure the voltmeter leads meet the terminals in the connector and
that there is good terminal to wire connection.
NOTE: Ensure the voltmeter leads are connected for positive polarity
Back probe the Evaporator Temperature Sensor Signal circuit between the Evapo-
rator Temperature Sensor harness connector and the A/C - Heater Control Module C1
harness connector.
Turn the ignition on.
Is the voltage below 0.10 volt?

All

Yes

Replace the A/C - Heater Control Module in accordance with the
Service Information. After repair is complete, rerun the Cooldown
Test.
Perform BODY VERIFICATION TEST - VER 1.

No

Repair the high resistance in the Evaporator Temperature Sensor
Signal circuit. After repair is complete, rerun the Cooldown Test.
Perform BODY VERIFICATION TEST - VER 1.

205

HEATING & A/C

COOLDOWN TEST TOO COLD TO START —

Continued

Symptom List:

ENGINE GAUGE RX FAILURE (ACTIVE)
PCM COMMUNICATION FAILURE (ACTIVE)
REFRIGERANT PRESSURE RX FAILURE (ACTIVE)
VIN RX FAILURE (ACTIVE)

Test Note:

All symptoms listed above are diagnosed using the same tests.

The title for the tests will be ENGINE GAUGE RX FAILURE
(ACTIVE).

When Monitored and Set Condition:

ENGINE GAUGE RX FAILURE (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the A/C - Heater Control Module does not receive any

one of the following messages from the PCM for more than 5 seconds: Battery Voltage,
Battery Temperature, Engine Coolant Temperature.

PCM COMMUNICATION FAILURE (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the A/C - Heater Control Module does not receive any

one of the following messages from the PCM for more than 8 seconds: Engine RPM, Vehicle
Speed.

REFRIGERANT PRESSURE RX FAILURE (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the A/C - Heater Control Module does not receive the

Refrigerant Pressure message from the PCM for more than 20 seconds.

VIN RX FAILURE (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the A/C - Heater Control Module does not receive the

VIN message from the PCM for more than 5 seconds.

POSSIBLE CAUSES

CHECK FOR ADDITIONAL HVAC DTCS

CHECK FOR PCM DTCS

A/C - HEATER CONTROL MODULE

PCM - NO MESSAGE TO A/C - HEATER CONTROL MODULE

206

HEATING & A/C

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, read HVAC DTCs.

Does the DRBIII

t display additional HVAC DTCs?

All

Yes

Return to the symptom list and choose the symptom(s).
Perform BODY VERIFICATION TEST - VER 1.

No

Go To

2

2

Turn the ignition on.
With the DRBIII

t, check the PCM for any DTCs.

Are any DTCs present?

All

Yes

Refer to the Powertrain Diagnostic Information.
Perform BODY VERIFICATION TEST - VER 1.

No

Go To

3

3

Turn the ignition on.
With the DRB in HVAC, Monitor Display, PCI Bus Msgs, look for the applicable
message and displayed value (

9A/C Hi Side Press: XX,9 9Veh Spd: XX,9 9Eng RPM:

XX,

9 9Coolant Temp: XX,9 9Batt Volts: XX,9 9Batt Temp: XX,9 9VIN Msg Pres: YES9).

Does the DRB display NO RESPONSE after the applicable message?

All

Yes

Replace and program the Powertrain Control Module in accor-
dance with the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

Replace the A/C - Heater Control Module in accordance with the
Service Information.
Perform BODY VERIFICATION TEST - VER 1.

207

HEATING & A/C

ENGINE GAUGE RX FAILURE (ACTIVE) —

Continued

Symptom:

EVAPORATOR TEMPERATURE SENSOR CIRCUIT OPEN (ACTIVE)

When Monitored and Set Condition:

EVAPORATOR TEMPERATURE SENSOR CIRCUIT OPEN (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the Evaporator Temperature Sensor/sensor circuit is

open.

POSSIBLE CAUSES

EVAPORATOR TEMPERATURE SENSOR

EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT OPEN

SENSOR GROUND CIRCUIT OPEN

A/C - HEATER CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the Evaporator Temperature Sensor harness connector.
Connect a jumper wire between the Evaporator Temperature Sensor Signal circuit
and the Sensor Ground circuit at the Evaporator Temperature Sensor harness
connector.
Turn the ignition on.
With the DRBIII

t in Sensor Display, read the Evaporator Temperature Sensor

voltage.
Does the DRBIII

t display: 0.0 volts?

All

Yes

Replace the Evaporator Temperature Sensor in accordance with
the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

Go To

2

2

Turn the ignition off.
Disconnect the A/C - Heater Control Module C1 harness connector.
Disconnect the Evaporator Temperature Sensor harness connector.
Measure the resistance of the Evaporator Temperature Sensor Signal circuit between
the A/C - Heater Control Module C1 harness connector and the Evaporator Temper-
ature Sensor harness connector.
Is the resistance below 5.0 ohms?

All

Yes

Go To

3

No

Repair the Evaporator Temperature Sensor Signal circuit for an
open.
Perform BODY VERIFICATION TEST - VER 1.

208

HEATING & A/C

 

 

 

 

 

 

 

Content   ..  50  51  52  53   ..