TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the Power Sliding Door Module C1 harness connector.
Disconnect the Sliding Door Motor connector.
Measure the resistance between ground and the Liftgate Open Driver circuit.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Sliding Door Open Driver wire for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

4

Turn the ignition off.
Disconnect the Power Sliding Door Module C1 harness connector.
Disconnect the Sliding Door Motor connector.
Measure the resistance between ground and the Sliding Door Close Driver circuit.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Sliding Door Close Driver wire for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Power Sliding Door Motor..

Perform BODY VERIFICATION TEST - VER 1.

1057

POWER DOORS - SLIDING

INCOMPLETE POWER CLOSE - TRANSISTOR SHORTED —

Continued

Symptom:

INCOMPLETE POWER CLOSE- VOLTAGE BELOW MINIMUM
LEVEL

When Monitored and Set Condition:

INCOMPLETE POWER CLOSE- VOLTAGE BELOW MINIMUM LEVEL

When Monitored:

Whenever the power sliding door is performing a power close opera-

tion.

Set Condition:

The PSD Module detects that the voltage is below 9.5 volts during the

power close operation.

POSSIBLE CAUSES

DTC PRESENT

MODULE VOLTAGE LOW

BINDING SLIDING DOOR

DRB OPERATING VOLTAGE LOW

POWER SLIDING DOOR MODULE - HIGH RESISTANCE

POWER SLIDING DOOR MOTOR

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power sliding door several times if possible.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display INCOMPLETE POWER CLOSE - VOLTAGE BELOW

MINIMUM LEVEL?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.

2

Examine the door for proper fit and alignment, loose/ hard or torn seals, worn teeth
on the track and gear (lower drive unit) or anything that would cause an obstruction
to proper operation.
Manually operate the other sliding door or of a known good vehicle and notice the
effort needed to open and close.
Compare the effort needed on the disabled door.
Does it take more effort to operate the sliding door than it should?

All

Yes

→ Refer to Service information for the related symptom(s).

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

1058

POWER DOORS - SLIDING

TEST

ACTION

APPLICABILITY

3

NOTE: Test the battery to ensure it is fully charged and in good condition
before proceeding.
Turn the ignition off.
Turn all lights and accessories off.
With the DRBIII

t in 9Sliding Door9 9Monitor Display9 9PCI Bus Info9 read the

9Battery Voltage9 and compare it to the 9PSD Bat Volts Input9.
NOTE: If the difference is greater than 0.5 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 0.5 volts?

All

Yes

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

4

Turn the ignition off.
Turn all lights and accessories off.
With the DRBIII

t in 9Sliding Door9 9Monitor Display9 9PCI Bus Info9 read the

9Battery Voltage9 and compare it to the 9PSD Bat Volts Input9.
Operate the power sliding door and observe the voltage difference.
NOTE: If the difference is greater than 1.6 volts, backprobe the Fused B(+)
at the module to verify.
Does the voltage vary more than 1.6 volts when the liftgate is operating??

All

Yes

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Locate and repair the reason for the
voltage drop.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Turn the ignition off.
Turn all lights and accessories off.
Remove the sliding door trim panel to gain access to the Power Sliding Door Module.
Backprobe voltmeter leads between the Fused B(+) and the Sliding Door Close Driver
circuits in the PSD C1 connector.
Open the sliding door.
Operate the power sliding door in the CLOSE position and observe the voltage
difference.
Does the voltage vary more than 0.2 volts when the sliding door is closing?

All

Yes

→ Replace the Power Sliding Door Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 6

6

If there are no possible causes remaining, view repair.

All

Repair

Check the wiring and connections from the module to the motor
for high resistance. If the wiring is okay, replace the Power Sliding
Door Motor assembly.
Perform BODY VERIFICATION TEST - VER 1.

1059

POWER DOORS - SLIDING

INCOMPLETE POWER CLOSE- VOLTAGE BELOW MINIMUM LEVEL —

Continued

Symptom:

INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE

When Monitored and Set Condition:

INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE

When Monitored:

Whenever the power sliding door is operating in the opening direction.

Set Condition:

The Full Open Switch was detected as closed before 200 hall effect pulses

were counted since the start of the open operation.

POSSIBLE CAUSES

DTC PRESENT

STICKING CABLES OR SWITCH

FULL OPEN SWITCH SENSE CIRCUIT SHORT TO GROUND

FULL OPEN SWITCH

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power sliding door several times if possible.
With the DRBIII

t, read ACTIVE DTCs.

Does the DRBIII

t display INCOMPLETE POWER OPEN - FULL OPEN SWITCH

FAILURE?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding cables or other
obstructions.
Perform BODY VERIFICATION TEST - VER 1.

2

Examine the door for proper fit and alignment, foreign material in the lower drive
unit or anything that would cause an obstruction to proper operation of the Full Open
Switch.
With the DRBIII

t in Inputs/Outputs, read the FULL OPEN SWITCH state.

Manually operate the door handle while monitoring the DRBIII

t.

Does the switch status change smoothly as the handle is pulled and released?

All

Yes

→ Go To 3

No

→ Refer to Service information for the related symptom(S).

Perform BODY VERIFICATION TEST - VER 1.

1060

POWER DOORS - SLIDING

 

 

 

 

 

 

 