Symptom: INCOMPLETE POWER CLOSE - OVERCURRENT When Monitored and Set Condition: INCOMPLETE POWER CLOSE - OVERCURRENT When Monitored: Anytime the Power Sliding Door is operating in the closing direction. Set Condition: The drive motor stall current of over 16 amps has been detected for over 500 ms. during a close operation. POSSIBLE CAUSES DTC PRESENT BINDING DOOR GROUND CIRCUIT OPEN SLIDING DOOR CLOSE DRIVER CIRCUIT SHORT TO GROUND CINCH/RELEASE MOTOR UNLATCH DRIVER CIRCUIT SHORT TO GROUND DOOR MOTOR CLUTCH DRIVER CIRCUIT SHORT TO GROUND POWER SLIDING DOOR MOTOR/CLUTCH TEST ACTION APPLICABILITY 1 With the DRBIII t, record and erase DTC’s. Turn the ignition off, wait 10 seconds, then turn the ignition on. t, read DTCs. Does the DRBIII t display INCOMPLETE POWER CLOSE - OVERCURRENT? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. Operate the 2 Examine the door for proper fit and alignment, loose/ hard or torn seals, worn teeth All Yes → Refer to Service information for the related symptom(s). Perform BODY VERIFICATION TEST - VER 1. No → Go To 3 1053 POWER DOORS - SLIDING |