BMW 3 (E46). Manual - part 310

 

  Index      BMW     BMW 3 (E46) - service repair manual 2006 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  308  309  310  311   ..

 

 

BMW 3 (E46). Manual - part 310

 

 

BMW
code

P-code

Fault type and
function

Signal type and
range

Explanation

45

Multi functional
steering wheel,
toggle-bit

Input binary
stream (0-12V)

Every 0.5 sec. a message that
includes a toggle bit (toggles
between 0->1 and 1->0) is
transmitted. Change bit is
monitored to indicate proper
function.

47

MS 43

Torque monitoring
level 1

DME internal
values logical

48

MS 43

Internal control
module

DME HW test
memory

49

ECU internal test

DME HW test

50

P1145
MS 42

Running losses
valve (3/2), final
stage

Output digital
on/off (active low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

MS 43

ECU internal test

DME HW test

51

MS 43

ECU internal test

DME HW test

52

Rear exhaust valve
flap

Output digital
steady (active low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

53

P1509

Idle control valve
opening coil

Output digital
pulse width (active
low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

55

P0155

Oxygen sensor
heater pre-cat
(Bank 2)

Output digital
pulse width (active
low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

56

Ignition feedback,
interruption at

Input analog (32V)

Check for correct signal
voltage. If voltage is 32V

BMW
code

P-code

Fault type and
function

Signal type and
range

Explanation

shunt resistor

(limitation voltage) then
secondary ignition voltage is
detected and shunt resistor
may be faulty.

57

P0325

Knock sensor 1
circuit, (Bank 1)
circuit continuity

Input analog
amplitude
(13-19kHz)

Plausibility check between
knock sensor amplitude
during knocking with internal
knock detection mapped DME
values.

59

P0330

Knock sensor 2
circuit, (Bank 2)
circuit continuity

Input analog
amplitude
(13-19kHz)

Plausibility check between
knock sensor amplitude
during knocking with internal
knock detection mapped DME
values.

61

P0141

Oxygen sensor
heater post-cat
(Bank 2)

Output digital
pulse width (active
low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

62

P0412

Secondary air
injection system
switching valve

Output digital
on/off (active low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

65

P0340

Intake cam position
sensor,
malfunction

Input analog
phase shift 0-5V

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

68

EVAP system,
purge control valve
circuit

Output digital
pulse width (active
low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

69

Relay fuel pump

Output digital
on/off (active low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output

BMW
code

P-code

Fault type and
function

Signal type and
range

Explanation

transistor and component
exists.

74

AC compressor
relay

Output digital
on/off (active low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

79

P0161

Oxygen sensor
heater post-cat
(Bank 1)

Output digital
pulse width (active
low)

DME final stage will set flag
whenever a short to ground, a
short to battery voltage or a
disconnection between output
transistor and component
exists.

83

P0335

Crankshaft position
sensor,
malfunction

Input digital
(0-12V)

Checks for correct signal
pattern and correct number of
expected flywheel teeth.

100

P0601

Internal control
module, memory
check sum or
communication

DME internal
values logical

Internal hardware test of
RAM, ROM, and Flash Prom.

103

P1519

VANOS faulty
reference value
intake

DME internal
values logical

Maximum VANOS adjustment
angle, checked at every
engine start must be within a
specified limit.

104

P1520

VANOS faulty
reference value
exhaust

DME internal
values logical

Maximum VANOS adjustment
angle, checked at every
engine start must be within a
specified limit.

105

P1522

VANOS stuck
(Bank 1) intake

DME internal
values

Monitoring of a desired
VANOS adjustment within a
predefined diagnostic time
limit.

106

P1523

VANOS stuck
(Bank 2) exhaust

DME internal
values

Monitoring of a desired
VANOS adjustment within a
predefined diagnostic time
limit.

109

P1580

Motor throttle valve
pulse width not
plausible

Output digital
pulse width
(0-12V)

Throttle position control
algorithm checks for problems
with mechanical coupling

BMW
code

P-code

Fault type and
function

Signal type and
range

Explanation

spring within motor throttle
body.

110

P1542

Pedal sensor
potentiometer 1

Input analog
(0-5V)

Failed signal range check
against predefined diagnostic
limits.

111

P1542

Pedal Sensor
Potentiometer 2

Input analog
(0-5V)

Failed signal range check
against predefined diagnostic
limits.

112

P0120
MS 42

Motor throttle valve
potentiometer 1

Input analog
(0-5V)

Failed signal range check
against predefined diagnostic
limits.

MS 43

Throttle position
sensor 1

Input analog
(0-5V)

Failed signal range check
against predefined diagnostic
limits.

113

P0120

Motor throttle valve
potentiometer 2

Input analog
(0-5V)

Failed signal range check
against predefined diagnostic
limits.

114

P1580
MS 42

Motor throttle valve
final stage

DME internal test

Final stage inside DME
(special H-bridge), will set
internal flag whenever a short
to ground, a short to battery
voltage or a disconnection
occurs.

MS 43

A second pedal
sensor range
check failure is
determined

DME internal
values logical

If pedal sensor malfunction is
determined, followed by a
second malfunction, a signal
is sent.

115

P1623
MS 42

Output voltage 5V
for potentiometer
operation 1

DME internal (5V)

Check for proper 5 volts
supply to potentiometers is
possible within a predefined
voltage limit.

MS 43

Range check for
throttle position
adaptation

Input analog
(0-5V)

Range check for closed
position of throttle sensors.

116

P1623

Output voltage for
potentiometer
operation 2

DME internal (5V)

Check for proper 5 volts
supply to potentiometers is
possible within a predefined
voltage limit.

 

 

 

 

 

 

 

Content   ..  308  309  310  311   ..