Volkswagen Golf / Golf GTI / Jetta. Manual - part 1034

 

  Index      Volkswagen     Volkswagen Golf / Golf GTI / Jetta - service repair manual 1999-2005 year

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  1032  1033  1034  1035   ..

 

 

Volkswagen Golf / Golf GTI / Jetta. Manual - part 1034

 

 

01-48

 

  

  

-  Enter adaptation value using VAG 1551 button 

pad. 

  

  

The last position of the kilometer reading must be 
rounded off to the nearest 10 kms. Therefore, a 
kilometer reading of 89627 produces an 
adaptation value of:  

  

  

0 8 9 6 3  

  

  

X     

  

  

  

Hundred thou.: 100000 ... 
655350 km  

  

X     

  

  

Ten thousands: 10000 ... 
90000 km  

  

  

X     

  

Thousands: 1000 ... 9000 km  

  

  

  

X     

Hundreds: 100 ... 900 km  

  

  

  

  

X   Tens: 10 ... 90 km  

  

  

  

  

  

Units: round up to next ten  

  

  

-  After entering adaptation value using VAG 1551 

button pad, 

Channel 9 Adaptation 0 

Q

Enter adaptation value 08963

     Indicated on display (example only):  

-  Press -Q- button to confirm input. 

Channel 9 Adaptation 8963 

Q

 

<-1 3->

     Indicated on display:  

The kilometer reading entered now appears in the 
display of the instrument cluster. If the displayed 
kilometer reading is not OK, e.g. false entry:  

-  Press -C- button and enter correct adaptation 

value again. 

Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)

13/2/2005

01-49

 

  

  

If the displayed kilometer reading in 
instrument cluster is OK:  

  

  

-  Press -Q- button to confirm input.  

Channel 9 Adaptation 8963 

Q

Store changed value?

     Indicated on display:  

-  Press -Q- button to confirm input.  

Channel 9 Adaptation 8963 

Changed value is stored

     Indicated on display:  

-  End odometer adaptation by 

pressing 

 button. 

Rapid data transfer 

HELP

Select function XX

     Indicated on display:  

-  Press buttons -0- and -6- to select 

"End Output" function 06. 

Rapid data transfer 

Q

06 End Output

     Indicated on display:  

-  Press -Q- button to confirm input.  

Rapid data transfer 

Help

Enter address word XX

     Indicated on display:  

The tester is now in basic function 
again.  

Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)

13/2/2005

01-50

 

  

   Distance impulse number (K-number), 

reading/confirming  

  

   Distance impulse number can only be 

read/confirmed on VDO instrument clusters.  

  

   Distance impulse number for MMO instrument 

clusters 

 Code control module, 

 

Page 01-

29

 .  

  

   Notes:  

  

  

 The distance impulse number is a constant 

used to calculate the speed indication and 
distance travelled.
 

  

  

 The distance impulse number (K number) 

cannot be changed using the "Adaptation" 
function!
 

  

  

 For instrument clusters with mile indicators, the 

distance impulse number is shown in 
kilometers. The trip impulse number for mile 
values can be calculated as follows:Trip 
impulse number for kilometer values x 1.609 = 
trip impulse number for mile values.
 

  

  

 Press the -C- button on the VAG 1551 to abort 

the "Read distance impulse number" function.  

Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)

13/2/2005

01-51

 

  

  

-  Connect scan tool VAG 1551, select operating 

mode 1 "Rapid data transfer", switch on ignition 
and enter address word 17 "instrument cluster". 

  

  

-  Press -Q- button to confirm input. 

  

  

-  Press 

 button until "Select function"appears in 

display. 

Rapid data transfer 

HELP

Select function XX

     Indicated on display:  

-  Press buttons -1- and -0- to select "Adaptation" 

function 10. 

Rapid data transfer 

Q

10 - Adaptation

     Indicated on display:  

-  Press -Q- button to confirm input. 

Adaptation 

Enter channel number XX

     Indicated on display:  

-  Press buttons -1- and -6- to select adaptation 

"channel 16". 

-  Press -Q- button to confirm input. 

Channel 16 Adaptation 3538 

<- 1 3 -> 

     Indicated on display (example only):  

Read/confirm distance impulse number, 

 code 

table, 

 

Page 01-32

 .  

Instrument cluster through m.y. 1999, On Board Diagnostic (OBD)

13/2/2005

 

 

 

 

 

 

 

Content   ..  1032  1033  1034  1035   ..