1GR-FE ENGINE CONTROL SYSTEM – SFI SYSTEM ES–23 ES (b) If the test value is between the minimum test limit and maximum test limit, the component is 4. MONITOR RESULT INFORMATION A/F Sensor Bank 1 Sensor 1 A/F Sensor Bank 2 Sensor 1 HO2 Sensor Bank 1 Sensor 2 HO2 Sensor Bank 2 Sensor 2 Catalyst - Bank 1 Catalyst - Bank 2 EVAP Monitor ID Test ID Scaling Unit Description $01 $8E Multiply by 0.001 V A/F sensor deterioration level $01 $91 Multiply by 0.004 mA A/F sensor current Monitor ID Test ID Scaling Unit Description $05 $8E Multiply by 0.001 V A/F sensor deterioration level $05 $91 Multiply by 0.004 mA A/F sensor current Monitor ID Test ID Scaling Unit Description $02 $07 Multiply by 0.001 V Minimum sensor voltage $02 $08 Multiply by 0.001 V Maximum sensor voltage $02 $8F Multiply by 0.0003 g Maximum oxygen storage capacity Monitor ID Test ID Scaling Unit Description $06 $07 Multiply by 0.001 V Minimum sensor voltage $06 $08 Multiply by 0.001 V Maximum sensor voltage $06 $8F Multiply by 0.0003 g Maximum oxygen storage capacity Monitor ID Test ID Scaling Unit Description $21 $A9 Multiply by 0.0003 No dimension Oxygen storage capacity of catalyst - Bank 1 Monitor ID Test ID Scaling Unit Description $22 $A9 Multiply by 0.0003 No dimension Oxygen storage capacity of catalyst - Bank 2 Monitor ID Test ID Scaling Unit Description $3D $C9 Multiply by 0.001 kPa Test value for small leak (P0456) $3D $CA Multiply by 0.001 kPa Test value for gross leak (P0455) $3D $CB Multiply by 0.001 kPa Test value for leak detection pump OFF stuck (P2401) $3D $CD Multiply by 0.001 kPa Test value for leak detection pump ON stuck (P2402) $3D $CE Multiply by 0.001 kPa Test value for vent valve OFF stuck (P2420) |