M161 ENGINE COOLING 1D2 -- 11

DAEWOO MY_2000

THERMOSTAT

1 Bolt (M6 X 25, 3 pieces)

9--11 NSm (80--97 lb-in)

. . . . . . . . . . . . . . . . . . . . .

2 Thermostat Cover

3 De--aeration Hose

4 Coolant Outlet Hose

5 Thermostat

6 O--ring

Removal & Installation Procedure

1. Drain the coolant from the radiator.
2. Loosen the hose mounting clip and remove the cool-

ant hose (3, 4).

3. Unscrew the three bolts (1) and remove the thermo-

stat cover assembly from thermostat housing.
Installation Notice

Tightening Torque

9 -- 11 NSm (80 -- 97 lb-in)

Do not separate the thermostat cover and thermo-

stat.

4. Replace the O--ring if necessary.
5. Check the leakage in the cooling system.

1D2 -- 12 M161 ENGINE COOLING

DAEWOO MY_2000

THERMOSTAT HOUSING ASSEMBLY

Preceding Work: Removal of viscous clutch

1a Bolt (M6 X 95, 2 pieces)

9--11 NSm (80--97 lb-in)

. . . . . . . . . . . . . . . . . . . . .

1b Bolt (M8 X 75, 2 pieces)

22.5--27.5 NSm (16.6--20.3 lb-ft)

. . . . . . . . . . . . .

1c Bolt (M8 X 35, 1 piece)

22.5--27.5 NSm (16.6--20.3 lb-ft)

. . . . . . . . . . . . .

2 Thermostat Housing Assembly

3 O--ring

4 De--aeration Hose

5 Coolant Outlet Hose

6 Coolant Bypass Hose

7 Tensioning Device Shock Absorber

8 Engine Hanger Brocket

M161 ENGINE COOLING 1D2 -- 13

DAEWOO MY_2000

Removal & Installation Procedure

1. Drain the coolant.
2. Remove the de--aeration hose (4), coolant outlet

hose (5) and coolant bypass hose (6).

3. Disconnect the coolant temperature sensor connec-

tor.

4. Unscrew the bolt (1c) and pry off the tensioning de-

vice shock absorber (7).
Installation Notice

Tightening Torque

22.5 -- 27.5 NSm

(16.6 -- 20.3 lb-ft)

5. Unscrow the bolts (1a, 1b) and remove the engine

hanger bracket and thermostat housing.
Installation Notice

Tightening

(1a)

9 -- 11 NSm

(80 -- 97 lb-in)

Tightening

Torque

(1b)

22.5 -- 27.5 NSm

(16.6 -- 20.3 lb-ft)

6. Replace the O--ring with new one.
7. Installation should follow the removal procedure in

the reverse order.

8. Check for leaks in cooling system.

1D2 -- 14 M161 ENGINE COOLING

DAEWOO MY_2000

FAN SHROUD

Removal & Installation Procedure

1. Unscrew two bolts from cooling fan shroud and re-

move the shroud.
Installation Notice

Tightening Torque

3 -- 7 NSm (27 -- 62 lb-in)

2. Installation should follow the removal procedure in

the reverse order.

 

 

 

 

 

 

 

Content   ..  100  101  102  103   ..